h) To reinstall the burners, reverse steps c) through g).
Caution: The burner openings must be positioned
properly over the valve orifices. Figure 18 (a).
Check proper assembly before fastening manifold in
place. Figure 18 (b).
33
33
e) Remove the manifold bracket and unscrew the two
wing nuts that hold the manifold to the cooking box.
Pull the manifold and valve assembly out of the
burners and carefully set it down. Figure 15.
View from behind
cooking box
Wing nuts
Figure 15
Guide screw
Figure 16
Crossover tube
Figure 17
Venturi fin
Figure 18
Figure 19
Check fit
around valve
Valve
orifice
Burner opening
Check fit around burner
Figure 14
d) Unlatch the Spider Stopper Guards and remove.
Figure 14.
(a)
(b)
i)
Reinstall the Spider Stopper Guards. Slightly rotate
the Spider Stopper Guards so that the seams are in
line with the Venturi fins. There should be no gaps in
the seams or in the fit around the burners and valves.
Figure 19.
CAUTION: If the Spider Stopper Guards do not fit
tightly, contact Weber-Stephen Customer Service.
f)
Slide the burner assembly out from under the guide
screw and washer in the corners of the cooking box.
Figure 16.
g) Lift and twist the burner assembly slightly, to separate
the crossover tube from the burners. Figure 17.
Remove the burners from the cooking box.