14 

Troubleshooting

Maintenance

Work must be carried out using regulation tools, and the operating and maintenance 

manual must be complied with for all work.

Maintenance 

interval

Maintenance 

point

Maintenance  

activity

Daily

Entire machine

– Clean unit 

– Check connecting cable 

and plug for exterior 

damage

Every 200  

operating hours

– Check bottle neck and 

bottle tube for wear, 

replace if necessary

Fault

Possible cause

Remedy

Interior concrete 

vibrator cannot be 

put into operation

Operating error 

Put the unit into operation as 

specified in the operating manual

Interior concrete 

vibrator is without 

function when 

switched on

Automatic shutoff

Shut down interior concrete vibrator 

and wait approx. 30 s before 

switching it back on

Interior concrete 

vibrator shuts off 

during compacting

Automatic shutoff

Do not operate the interior concrete 

vibrator unless the entire bottle 

body is covered by concrete

A creepage current 

can be detected 

on the conductive 

parts of the unit 

(leakage current)

Grounding conductor 

not present

Check / replace  connecting  cable

Ground fault 

circuit interrupter 

missing / defective

Check / replace ground fault circuit 

interrupter

Power distribution 

on site not grounded

Check power distribution on site, 

provide for proper grounding of 

power distribution on site

Summary of Contents for IVUR 40

Page 1: ...1 Operating and Maintenance Manual IVUR 40 IVUR 50 IVUR 58 0242015 0243015 0244015...

Page 2: ...2...

Page 3: ...Graphic presentation 9 Technical data 10 Transport 12 Activities prior to starting work 12 Electrical connection 12 Connecting the interior concrete vibrator to the converter 12 Initial operation 13 S...

Page 4: ...intenance manual you help avoid hazards reduce repair and downtime costs and increase the reliability and service life of your interior concrete vibrator This operating and maintenance manual must alw...

Page 5: ...is designed exclusively for compacting concrete Any other use of the interior concrete vibrator is considered to be improper use for which the owner shall be exclusively responsible All liability is...

Page 6: ...nutes have passed since pulling the plug out of the power outlet as the capacitors built into the converter section require this amount of time to discharge According to VDE regulation 0100 part 410 H...

Page 7: ...Prior to restarting malfunctions of the interior concrete vibrator that have occurred must be corrected Maintenance The power plug of the interior concrete vibrator must be unplugged prior to any rep...

Page 8: ...executed in areas that are suitable and have been approved for this purpose oil separator amongst others Disposal All operating fluids and auxiliary materials must be disposed of in an environmentall...

Page 9: ...9 3 5 4 2 1 6 Overall view IVUR 1 Plug 2 Connecting cable 3 Switch 4 Converter 5 Protective tube shielded in accordance with EMC Directive 6 Interior concrete vibrator Graphic presentation...

Page 10: ...t Operating weight CECE in kg 14 16 17 Effective diameter approx mm 400 500 600 Dimensions Vibrator diameter mm 40 50 58 Vibrator length mm 330 370 420 Protective tube length mm 5000 5000 5000 Weight...

Page 11: ...11 1 2 3 1 Serial number 2 Year of manufacture 3 Type description...

Page 12: ...concrete vibrator into operation make sure the mains voltage 1 corre sponds to the voltage specified on the rating plate The connection must be made to a 230 Volt 50 Hz AC power source The power sour...

Page 13: ...to operation by pressing the switch 1 The interior concrete vibrator starts up Shutdown Shut down the interior concrete vibrator by pressing the switch 1 Pull the plug out of the power outlet Donotpul...

Page 14: ...operating manual Interior concrete vibrator is without function when switched on Automatic shutoff Shut down interior concrete vibrator and wait approx 30 s before switching it back on Interior concre...

Page 15: ...gnal missing Electronics defective Yellow LED is lit permanently Converter experiencing an error Output voltage and output frequency missing Yellow LED flashes 2 x in rapid succession Short circuit or...

Page 16: ...16 Frequency converter Circuit diagram IVUR...

Page 17: ...17...

Page 18: ...18...

Page 19: ...19...

Page 20: ...rMT youtube com MyWeberMT Weber Maschinentechnik GmbH Im Boden 5 8 10 57334 Bad Laasphe Germany Telefon 49 2754 398 0 Fax 49 2754 398 101 info webermt de www webermt de 085105041 104 IVUR_2020_06_EN O...

Reviews: