16
Lexus GS 450h
Fuel Connection
CAUTION!
Open the vehicle's tank-cap lock, ventilate the tank and then re-close the tank lock.
Catch any fuel running off with an appropriate container.
Install fuel line and metering pump cable harness so that they are protected against stone impact.
Unless specified otherwise, always fasten using cable clips.
Fit the fuel line and cable harness with edge protectors around sharp edges.
WARNING!
The fuel line and cable harness to the metering pump should be installed based on Cable Harness
diagram or page 7.
1
Mecanyl fuel line
2
Ø 10mm hose clamps [2x]
3
Hose section
Connec-
ting to the
heater unit
Insert the heater unit cable harness and
metering pump cable harness in the Ø 10mm
hose shaft
1
.
Wrap the tube ends with insulation tape.
Installing
lines
Run the tube shaft
1
, the Mecanyl fuel pipe
and the metering pump cable harness along
the original vehicle lines to the underbody.
Installing
lines
29
2
1
2 3
30
1
31
1