Webasto Thermo Pro 50 Eco Operation Manual Download Page 3

3

1. Webasto heaters must be switched “off” when re-fueling at filling stations to prevent the risk of

explosion.  Please review the owner’s manual for safety and use instructions.

2. The year in which the heater was used for the first time must be permanently displayed on the factory plate

by deleting the inapplicable years from the plate. 

3. The heater must not be operated without at least 20% brand name anti-freeze in the water of the heating

circuit.

4. The heaters are not designed for heating hazardous substance transport compartments. 

5. Claims can only be made if it can be verified that the claimant has complied with the servicing and safety

instructions. 

6. The heater may not be operated in enclosed spaces (such as garages) as a result of the risk of

poisoning and asphyxiation, even if a timer is used. 

7. The heater must be checked by Webasto-trained personnel at the latest at the start of the cold weather

period. 

8. In the event of long-lasting heavy smoke development, unusual combustion noises or a smell of fuel or if

the heater suffers continuous fault cut-outs with error messages (flashing code), it must be shut down by
removing the fuse and must not be reused until it has been inspected by Webasto-trained personnel. 

9. Wherever flammable vapors or dust may form, the heater must be switched off as a result of the

risk of explosion.  

10.May only be operated with the fuel specified on the rating plate and at the nominal voltage specified on

the rating plate.

11.The temperature in the area around the heater must not exceed 85 °C / 185° F (storage temperature). If

the temperature exceeds this level there is a risk of permanent damage to the electronics systems. 

12.Non-compliance with the installation instructions and the warnings contained therein will lead to the

exclusion of all liability by Webasto. The same applies if repairs are carried out incorrectly or by untrained
technicians or with the use of parts other than genuine spare parts. This will result in the invalidation of the
type approval for the heater unit.

13.To prevent mechanical parts seizing, the heater should be operated for approx. 20 minutes once a month. 

14.The heater must be inspected every 2 years by a Webasto-trained specialist at the beginning of the heating

season or earlier.

15.Do not stand on the heater and do not place any heavy items on the heater. 

16.Do not place any items of clothing, textiles or similar materials over the heater. 

17.The current of hot air in the heater must not be restricted or blocked by highly flammable substances or

materials such as rags, cleaning wool, etc.

18.The heater must not be cleaned with a high pressure cleaner.

Maintenance and Safety Instructions

Summary of Contents for Thermo Pro 50 Eco

Page 1: ...1 Operation Manual Thermo Pro 50 Eco D Diesel...

Page 2: ...ur complete satisfaction by the workshop service center which installed it In these operating instructions we would like to once again provide you with an overview of the safe use of this product To b...

Page 3: ...er flammable vapors or dust may form the heater must be switched off as a result of the risk of explosion 10 May only be operated with the fuel specified on the rating plate and at the nominal voltage...

Page 4: ...in the combustion chamber is ignited Flame is detected At this time the heater is working and produces heat Switch Off Switching off the heater stops combustion The operating indicator light remains o...

Page 5: ...glish Duration Duration allows user to select the heater runtime of the heater Set range is between 10 120 minutes selectable by 10 minute increments Note Duration time for all timers will default to...

Page 6: ...ch the Webasto SmarTemp Control fx will shut the heater off A warning LED and message will appear after 8 minutes of low voltage The warning will remain on for 2 minutes before the heater is shut off...

Page 7: ...than 20 seconds Control unit defective Overheating Effects The fuel supply is stopped if the heater overheats The heater continues to run in the same way as if it is switched off manually After the he...

Page 8: ...8 Webasto Thermo Comfort N A Inc 15083 North Road Fenton MI 48430 Technical Assistance Hotline USA 800 860 7866 Canada 800 667 8900 www webasto us www techwebasto com Org 5 2015 Rev 11 2015...