ProMaster
London
30
NOTE: The bleeder valve must be
the highest point in the cooling
system while bleeding and must
face up when installed.
43.
Using a length of 5/8” heater
hose and a bleeder valve (21, 22,
55), connect the return (top) port
of the London to the coolant
valve as shown.
44.
Connect the 5/8” hose (21, 55)
to the supply port on the London.
Route the hose through the hole
in the floor. Trim the coolant
hose, leaving enough hose to
reach the coolant pump installed
earlier.
45.
Connect the return hose (21, 55)
to the inlet side of the coolant
valve. Route the hose through the
hole in the floor.