- 9 -
Press
or
directly to adjust the desired water temperature (parameter d, range:.15—40
℃
), the
data will be saved in 3 seconds.
Or you can adjust the Parameter d to set your desired water temperature.
5.4 Parameter checking& adjusting
Hold
button for 5 seconds,
it will enter the parameter checking, Press
or
to check the below
parameters.
Then press
again to enter the current parameter adjusting, press
or
to make the adjustment,
then press
to save the setting.
Parameter
Description
Range
Default
Remark
A
Inlet water temp.
-19
~
99
℃
Real data
b
Piping temp.
-19
~
99
℃
Real data
C
Ambient temp.
-19
~
99
℃
Real data
d
Desired water temp.
15
℃~
40
℃
27
℃
Adjustable
H
Return water temp. difference
1
℃~
10
℃
2
℃
Adjustable
J
Power-fail protection
0
~
1
1 (Yes)
Adjustable
O
The lowest ambient temp. for running
0
℃~
15
℃
11
℃
Unadjustable
5.5 Restroe factory setting
Hold
and
for 10 seconds to restore the factory settings.
NOTE: the heat pump can run only if the water circle/filtration system is running.
NOTE: The other parameters which is not shown on below sheet is for reservation, no real function.
Summary of Contents for WMP-003
Page 2: ......
Page 9: ... 7 4 Electrical wiring 4 1 Swimming pool heat pump wiring diagram WMP 003 004 WMP 005 ...
Page 23: ... 21 4 Elektrische bedrading 4 1 Bedradingsschema WMP 003 004 WMP 005 ...
Page 30: ......
Page 31: ......
Page 32: ......