- 4 -
2. Dimension (mm)
WMIP-003/004/006
3.Installation and connection
Attention:
Please observe the following rules when installing the heat pump:
1. Any addition of chemicals must take place in the piping located
downstream
from the heat pump.
2. Always hold the heat pump upright. If the unit has been held at an angle, wait at least 24 hours before
starting the heat pump.
3.1 Heat pump location
The unit will work properly in any desired location as long as the following three items are present:
1. Fresh air
–
2. Electricity
–
3. Swimming pool filters
The unit may be installed in virtually any
outdoor
location as long as the specified minimum distances to other
objects are maintained. Please consult your installer for installation with an indoor pool.
ATTENTION:
Never install the unit in a closed room with a limited air volume in which the air expelled from
the unit will be reused, or close to shrubbery that could block the air inlet. Such locations impair the
continuous supply of fresh air, resulting in reduced efficiency and possibly preventing sufficient heat output.