- 16 -
A
Fan Speed
: Signal of Water pump
: Wi-Fi function
Attention
:
With the indication of the functions or key parts, it is helpful for service
team to maintain or repair the heat pump.
6.9 Manual defrosting
Hold
and
for 3 seconds to start Manual defrosting function.
6.10 Factory setting recovery
Hold
and
and
and
for 5 seconds to recover factory setting.
6.11 Running Parameter checking
Press
to enter the Running parameters checking, then press
and
to check the
below parameters as below:
N
°
Description
Unit
C01
Ambient temperature
°
C
C02
Evaporator coil temperature
°
C
C03
Exhaust temperature
°
C
C04
Return temperature
°
C
C05
Reserved
°
C