5
http://support.weathermatic.com
To return to automatic operation, turn the SET dial and the SELECT
dial to their original positions before you started to run the zones
manually. The manual operation that you selected will finish and
the timer will return to automatic operation as scheduled.
4.4 Running the Controller on a 3 Minute Cycle
Turn the SET dial to the 3 MINUTE TEST position and the SELECT
dial to the RUN ALL position. This will run all zones that have a
runtime in any program for 3 minutes.
To return to automatic operation, turn the SET dial and the SELECT
dial to their original positions before you started to run the zones
manually. The manual operation that you selected will finish and
the timer will return to automatic operation as scheduled.
4.5 Clearing All Scheduled Programs
Turn the SET dial to the OFF position and the SELECT dial to the
RUN ALL position. Press the + and – buttons simultaneously and
hold for 3 seconds. The LCD screen will go blank indicating that
all scheduled programs have been cleared. When you release the
buttons the time will reappear.
4.6 Turning the Controller Off
To discontinue watering when the timer is in operation or to
prevent automatic operation, turn the SET dial to the OFF position.
To return to automatic operation, return the SET dial to the RUN
position.
5.0 Maintenance
5.1 Battery Replacement
The two Alkaline AA batteries are replaceable. Remove the four
screws that are located on the bottom of the unit. Replace the
two batteries making sure you place them in the correct polarity
position. Then carefully replace the battery cover and the four
screws.
NOTE:
Make sure not to get any water in the battery housing as
you are replacing the batteries. To seal the battery cover properly,
all 4 screws must be used.
5.2 Plunger Cleaning
To clean the plunger and plunger tube gently remove the plastic
plunger retainer with needle-nosed pliers. Clean debris from the
plunger and plunger tube. Then replace the plunger retainer.
5.0 Maintenance
Summary of Contents for SoloRain 8024 DC Series
Page 2: ......
Page 12: ...ADSR 8024 MN_REVB ...