Installation Procedure
1) Switch off the mains electrical supply.
3) Check that rating shown on luminaire label
conforms with mains electrical supply.
(example)
05/19 IP66
VLS420-LED
220-240V / 50-60 Hz
131-XXXX
SOE XXXXXXX
LED 3000K 18W
item no. XXX
2) Remove wall flange
A
from cover
B
by releasing
screws
C
.
Fixture is intended to be mounted over a UL listed
junction box (not supplied by WE-EF), use provided
wall plate to cover boxes larger than the outer
dimensions of the luminaire.
4) Determine positions for four fixing screws
D
.
Drill relevant holes
E
and insert wall plugs
F
.
ATTENTION:
Ensure not to damage any electrical
cable, water pipe or other items drilling holes.
5) Feed the mains supply cable
G
(and the second
cable
H
for through wiring, if required) through
the cable gland
I
at the side of the wall flange,
while setting and fixing wall flange in position.
The cable gland
I
is suitable for cable diame-
ters 0.276 to 0.472 in.
6) Ensure the point arrow mark
R
on the wall
flange aims upwards and that the luminaire is
properly oriented.
Fix the wall flange by inserting and tightening
screws
D
.
7) Connect mains supply leads to respective
terminals in terminal connectors
J
as follows:
Non dimmable luminaires
Phase to L1, Neutral to N and Earthing to
0-10V
Phase to L, Neutral to N, 0-10V+ to D+,
0-10V- to D- and Earthing to
Luminaire Replacement
The LED module can be replaced by qualified per-
sonnel with appropriate professional qualifications
and with standard tools. To do this, disconnect
the luminaire from the power supply and open it.
Replace the LED module and close it again. Make
sure that the seal is correctly positioned and close
the luminaire carefully.
8) Tighten cable gland(s)
I
.
9) Reposition cover
B
on wall flange
A
and secure
in position by evenly tightening the screws
C
5 Nm (44.3in-lb).