Installation Procedure
1) Switch off and isolate the mains electrical supply A.
2) Loosen screws of wire mounting suspension clamps B
(fig.2).
3) Hang luminaire with wire mounting suspension clamps
to the wire.
4) Tighten screws of clamps B.
5) In case the luminaire is not to be angled horizontally,
the wire mounting suspension can get adjusted to
inclinations. To do this loosen the screws P of the
clamps, adjust luminaire and tighten screws again
(fig.1).
4
6) Loosen screws E on cover F of the wire mounting
suspension and remove the cover (fig. 2).
7) Insert the corresponding wire length cut to suit con-
necting line A, through the cable gland H inside the
connecting box G (fig. 2). For optional through wiring
there is an additional cable gland H equipped with a
plug which can be removed if required.
8) Connect cable to the corresponding marked contacts of
the terminal clamp. Compare local voltage and frequen-
cy with the data shown on luminaire label.
For class II applications the earth protection is not
applicable. All leads and connections must match
class II standards. Use the strain relief.
9) Firmly tighten cable gland H and reposition cover E
onto the connecting box G and tighten it.
10) The luminaire can get adjusted up to 25
°
to each side,
to illuminate an object (fig. 3). For this, loosen the screws
Q and the cable gland
I
. Pull out the connecting line,
which runs from the wire mounting suspension inside
the luminaire, as much as required.
When luminaire is adjusted, firmly tighten screws Q
and the cable gland.