The product must be installed and maintained by a 

VXLWDEO\TXDOLĥHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW

 

building/construction and/or electrical regulations and relevant legislation.

Warning:

6ZLWFKRĪPDLQVHOHFWULFDOVXSSO\SULRUWRLQVWDOOLQJDQGFRQQHFWLQJWKHOXPLQDLUH

Notice:

,IWKHOXPLQDLUHLVPRGLĥHGE\DQ\ERG\RWKHUWKDQWKHRULJLQDOPDQXIDFWXUHUWKHQWKHZDUUDQW\ZLOO

no longer be valid and shall become the full responsibility of the modifying person/organisation.  
Claims based on defects attributable to improper installation and/or application, and the consequences 
thereof, are excluded.

Attention: The luminaire is factory-sealed and does not need to be opened during installation. 
 
The installation on site must comply with local and/or national health and safety regulations.

Summary of Contents for PSY414

Page 1: ... respective primary Type 1 and secondary Type 2 surge arrestors in compliance with EN61643 11 IEC61643 1 Warning Ensure that all required surge protection measures are in place and activated prior to luminaire installation Also disconnect luminaires before operating high power devices such as for example electrical arc welders Do not open during installation This product is factory sealed Refer to...

Page 2: ...IK10 Class I ta 40 C Weight lb for PSY414 29 3 for PSY424 35 5 for PTY414 30 9 for PTY424 41 9 Accessories Planted root Galvanised steel lb ESV2 for PSY414 424 300 9115 8 4 ESV2 Bollard PSY414 PSY424 PTY414 PTY424 ...

Page 3: ...pecial maintenance work is required Do not use high pressure cleaners In case of component failure due to abnormal circumstances or at end of life replacement must be carried RXW E D VXLWDEO TXDOLĥHG DQG WUDLQHG SURIHVVLRQDO Warning Do not open luminaire while mains supply is switched on ...

Page 4: ...WKH OXPLQDLUH LV PRGLĥHG E DQ ERG RWKHU WKDQ WKH RULJLQDO PDQXIDFWXUHU WKHQ WKH ZDUUDQW ZLOO no longer be valid and shall become the full responsibility of the modifying person organisation Claims based on defects attributable to improper installation and or application and the consequences thereof are excluded Attention The luminaire is factory sealed and does not need to be opened during install...

Page 5: ...WULFDO VXSSO 4 Remove terminal box cover C as shown 2 Remove sleeve A from post B C 3XOO FDEOH WKURXJK FHQWUH KROH DQG IDVWHQ ĦDQJH plate E with provided fasteners to ground Ensure proper orientation of terminal box An optional planted root is available E Note Planted root installation instruction is available in additional document ...

Page 6: ...block G Lock cable s with strain relief s 7 Return terminal box cover C C 5 Check that rating shown on luminaire label conforms with mains electrical supply example PSY424 120 277 60Hz 114 XXXX SOE XXXXXXX LED 4000K 18W item no XXX 08 18 IP66 8 Place sleeve A over post B with sticker I pointing up as shown I A B G F D ...

Page 7: ...K with Torx 25 tool supplied by WE EF 9 Align sleeve A LQWR ĦDQJH SODWH E good and bad engagement E A K J 12 Place head K over sleeve A and check for alignment ĦXVK A K 11 Hold head K under arm Grab socket L connect and tighten with plug M K M L ...

Page 8: ...7 N 13 Tighten recessed screws N gradually in alter nating sequence 6 Nm 53 1 in lb with Torx 30 tool supplied by WE EF 14 Return countersunk screws J into head and tighten ...

Page 9: ...www we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com TO9245W0422 WE EF 2022 Technical specifications are subject to change ...

Page 10: ...WE EF LIGHTING Installation and Maintenance Instructions Planted Root ESV4 ESV2 ESV6 ...

Page 11: ...4 300 0586 ESV4 300 0464 ESV4 300 0459 Suitability 1 KTX234 2 KTY234 3 ZFY230 4 GRY224 5 Short post Suitability 1 XRY334 2 XRZ334 3 RRY334 4 RRZ334 Suitability 1 CFY259 2 GRY234 3 RRY324 4 RRZ324 5 XRY324 6 XRZ324 Suitability 1 QSI254 ...

Page 12: ...3 Planted Root ESV2 300 9115 ESV6 300 0824 ESV6 300 0457 Suitability 1 PSY414 424 Suitability 1 AML C 2 FLA461 Suitability 1 LTM440 2 LTM444 3 AMW C 4 AMF C 5 AMF S 6 AML C ...

Page 13: ...t as shown base plate is parallel to the pathway For this installation use M12 bolts supplied 2 Please note ESV4 and ESV6 must be RULHQWDWHG FRUUHFWO IRU GLĪHUHQW SURGXFWV In both instances conduit entry can be rotated to match cable routing When the ESV is being installed for following products KTY234 KTX234 ZFY230 CFY259 FLA461 please orientate the planted root as shown base plate is at an angle...

Page 14: ...supplie 7 Place the ESV in the form work for concrete pad ensuring orientation position and levels are correct Ensure all openings on ESV are EODQNHG RĪ LQFOXGLQJ PRXQWLQJ SODWH KROH 8 Fit the nominated bolts through mounting ĦDQJH QVXUH VHYHUDO WKUHDGV IHHG WKURXJK WKH SODWH DQG WDSH RĪ WRS DQG ERWWRP ROWV DUH LQVHUWHG WR SURWHFW WKUHDGV RĪ SODWH DQG QHHG WR EH UHPRYHG IRU ĥWWLQJ LQVWDOODWLRQ aft...

Page 15: ...ete paver or soil Ensure WKDW IRU DQ LQVWDOODWLRQ PRXQWLQJ ĦDQJH PXVW EH ĦXVK RU KLJKHU WKDQ VXUURXQGLQJ VXUIDFH level IWHU FRQFUHWH KDV FXUHG IRU VSHFLĥHG WLPH UHPRYH EODQNLQJ DQG EROWV QVWDOO ĥWWLQJ as per luminaire instructions onto mounting ĦDQJH Concrete Paver Soil ...