background image

1

Facade and Ceiling Washlights

Wand- und Deckenfluter

Lampen / Lamps

HIT- DE 70-400W . . . . . . . . . . . . . . . . . . . . . . . . . .RX7s, Fc2

HST-DE 70-400W . . . . . . . . . . . . . . . . . . . . . . . . . .RX7s, Fc2

Schutzart / Protection: IP66

Schutzklasse / Class I, II, 

, ta = 40°C, tw = 130°C

Windangriffsfläche / Windage area  . . . . . . . . .max 0,15 m

2

Gewicht /Weight   . . . . . . . . . . . . . . . . . . . . . . max. 21,6 kg

Lichtpunkthöhe / Mounting height   . . . . . . . . . . . . . 4-12 m

Installation

The luminaire must be installed and maintained by a suit-

ably qualified person in compliance with latest construc-

tion and electrical regulations and relevant legislation. 

The given information from the lamp manufacturer about

the correct lamp, operation and maintenance are strictly 

to be observed.

The minimum distance to the illuminated object has to 

be observed (see sign 

inside of luminaire).

Montage

Montage und Wartung darf nur von geschultem Fach per -

sonal mit entsprechender beruflicher Quali fi kation in Über -

einstimmung mit den neuesten elektrischen Installa tions-

und Sicherheitsvorschriften durchgeführt werden.

Die Hinweise der Leuchtmittelhersteller der einge setzten

Lampe für Betrieb und Wartung sind unbedingt zu beachten.

Der Mindestabstand zu beleuchteten Gegenständen (siehe

Bildzeichen

in der Leuchte) ist unbedingt einzuhalten.

560

210

195

ø 140

ø 20

ø 13

ø 180

670

210

235

PIA240

PIA260

Montagearten / Mounting options

Reviews: