background image

Do not open during installation

This product is factory-sealed. 
Refer to the instructions contained in this 
document for details.

Surge Protection

This product features built-in surge protection circuitry in compliance with 

applicable standards.

For comprehensive protection of a luminaire installation against lightning and  

electrical surges, it is essential to cover mains supply and data input lines at  

the distribution board level, by using respective primary (Type 1) and secondary  

(Type 2) surge arrestors in compliance with EN61643-11/IEC61643-1.

Warning

Ensure that all required surge protection measures are in place and activated  

prior to luminaire installation. Also, disconnect luminaires before operating 

high-power devices such as, for example, electrical arc welders.

WE-EF LEUCHTEN

Installation and Maintenance

Instructions 

Pole Mounted Luminaire

PFL540

Summary of Contents for PFL540

Page 1: ...trical surges it is essential to cover mains supply and data input lines at the distribution board level by using respective primary Type 1 and secondary Type 2 surge arrestors in compliance with EN61643 11 IEC61643 1 Warning Ensure that all required surge protection measures are in place and activated prior to luminaire installation Also disconnect luminaires before operating high power devices s...

Page 2: ...minaire PFL540 330 590 867 90 ø 60 x 100 ø 76 x 80 IP66 IK08 Class I ta 25 C Optional side entry version for ø 60 x 80 mm spigot on request Weight kg for PFL540 15 Tools required 5 mm allen key 6 mm allen key ø 9 14 mm ...

Page 3: ...pecial maintenance work is required Do not use high pressure cleaners In case of component failure due to abnormal circumstances or at end of life replacement must be carried out E D VXLWDEO TXDOLƂHG DQG WUDLQHG SURIHVVLRQDO Warning Do not open luminaire while mains supply is switched on ...

Page 4: ...WKH OXPLQDLUH LV PRGLƂHG E DQ ERG RWKHU than the original manufacturer then the warranty will no longer be valid and shall become the full respon sibility of the modifying person organisation Claims based on defects attributable to improper installation and or application and the consequences thereof are excluded Attention The luminaire is factory sealed and does not need to be opened during insta...

Page 5: ... luminaire in position Tighten set screws F with a torque of 10 Nm 4 Reposition cover C and retighten screws B Option 1 Pole mounted Option 2 Side entry 2 Check that rating shown on luminaire label conforms with mains electrical supply example PFL540 220 240V 50 Hz 1 10 108 XXXX SOE XXXXXXX LED 4000K 48W item no XXX 09 19 IP66 A F B E C A F C B E ...

Page 6: ...5 L N Supply cable 5 Trim mains cable A to the desired length and connect the leads to their respective terminals at the base of the pole L Phase N Neutral Earthing ...

Page 7: ...nd Tel 41 22 752 49 94 Fax 41 22 752 49 74 info switzerland we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 LQIR DVLDSDFLƂF ZH HI FRP WE EF LIGHTING Australia Tel 61 3 8587 0444 Fax 61 3 8587 0499 info australia we ef com WE EF LIGHTING United States of America Tel 1 724 742 0030 Fax 1 724 742 0035 info usa we ef com TO9266W0520 WE EF 2020 7HFKQLFDO VSHFLƂFDWLRQV DUH subject ...

Reviews: