WE-EF FLC301 Installation And Maintenance Manual Download Page 11

2

Installation

The product must be installed and maintained by a 

VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWK

 

latest building/construction and/or electrical 

regulations and relevant legislation. 

The EM1-2 short post can be mounted either to a 

planted root or to an anchor bolt assembly secured 

in a cast concrete foundation. It is assumed that 

the mounting option chosen has been designed and 

constructed to satisfy prevailing load, location and 

soil type conditions, and is ready to receive the EM1-2 

short post.

Warning: 

6ZLWFKRIIPDLQVHOHFWULFDOVXSSO\SULRUWR

installing and connecting the luminaire. 

Notice: 

,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU

WKDQWKHRULJLQDOPDQXIDFWXUHUWKHQWKHZDUUDQW\ZLOO

no longer be valid and shall become the full 

responsibility of the modifying person/organisation. 

Claims based on defects attributable to improper 

installation and/or application, and the consequences 

thereof, are excluded. 

7KHLQVWDOODWLRQRQVLWHPXVWFRPSO\ZLWKORFDODQGRU

national health and safety regulations. 

Installation Procedure

1)  Ensure mounting surface 

A

 is clean and free of 

debris.

2)  Ensure anchor bolts

 C 

suit hole pattern in short 

SRVWpVƃDQJHSODWH

 E 

and feature appropriate, 

levelled protrusion from surface

 A

.

3)  Place rubber patch

 I 

on mounting surface 

A

.

4)  Mount short post 

B

. Adjust nuts

 D 

DQGZDVKHUV

 H 

on anchor bolts

 C 

and ensure the short post

 B 

is 

perpendicular to the ground.

5) Secure cover

 F 

E\WLJKWHQLQJFRYHUVFUHZV

 G 

to the 

ƃDQJHSODWH

Summary of Contents for FLC301

Page 1: ...e primary Type 1 and secondary Type 2 surge arrestors in compliance with EN61643 11 IEC61643 1 Warning Ensure that all required surge protection measures are in place and activated prior to luminaire...

Page 2: ...ted Projector IP66 IK08 Class I Ta 40 C Weight kg for FLC301 Surface mounted 0 8 Mounting Accessories Short post EM1 for FLC301 Surface mounted 145 9200 Installation instruction is available in additi...

Page 3: ...ecial maintenance work is required Do not use high pressure cleaners In case of component failure due to abnormal circumstances or at end of life replacement must be carried out E D VXLWDEO TXDOL HG D...

Page 4: ...ed The installation on site must comply with local and or national health and safety regulations Important When mounting luminaires on concrete or surfaces containing limestone content WE EF recommend...

Page 5: ...ing shown on luminaire label conforms with mains electrical supply example HWHUPLQH SRVLWLRQ IRU 67 LQJ VFUHZV D Drill relevant holes E and insert wall plugs F Warning Ensure not to damage any electri...

Page 6: ...7R PRXQWLQJ DQJH A insert and tighten screws D The pre installed packing ring H is suitable for cable diameters 7 to 9 5 mm For larger cable diameters 9 to 12 mm use the auxiliary packing ring supplie...

Page 7: ...6 9 For accessory Linear Spread Lens IO 180 Turn frame K to set desired orientation of light K...

Page 8: ...d Tel 41 22 752 49 94 Fax 41 22 752 49 74 info switzerland we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 LQIR DVLDSDFL F ZH HI FRP WE EF LIGHTING Australia Tel 61 3 8587 0444 F...

Page 9: ...WE EF LEUCHTEN Installation and Maintenance Instructions Accessory Short post Install...

Page 10: ...1 Accessories Suitability 1 FLB100 Surface mounted 2 FLC300 Surface mounted 3 FLD100 Surface mounted Short post...

Page 11: ...RGL HG E DQ ERG RWKHU WKDQ WKH RULJLQDO PDQXIDFWXUHU WKHQ WKH ZDUUDQW ZLOO no longer be valid and shall become the full responsibility of the modifying person organisation Claims based on defects attr...

Page 12: ...3...

Page 13: ...G Tel 41 22 752 49 94 Fax 41 22 752 49 74 LQIR VZLW HUODQG ZH HI FRP WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 LQIR DVLDSDFL F ZH HI FRP WE EF LIGHTING Australia Tel 61 3 8587 0444 F...

Reviews: