3

0:  . . . . . . . . . . . . . . . . . . . .

 

12 LED 24W / 36W / 52W

FLC240:   . . . . . . . . . . . . . . . . . . . 24 LED 48W / 72W / 104W

FLC260:   . . . . . . . . . . . . . . . . . . 36 LED 72W / 108 W / 155W

Protection: IP66, 

IK08 (PMMA), IK06 

(

Safety glass lens)

 

Class I, ta = 25°C

Installation 

The product must be installed and maintained by a suitably

 

qualified professional in compliance with latest building/

construction and/or electrical regulations and relevant 

legislation.

Warning:

 

Switch off 

and isolate 

mains electrical supply 

prior to

 

installing and connecting the luminaire. Do not open 

the 

luminaire while mains supply is switched on.

Notice:

 

If the luminaire is modified by anybody other than

 

the original manufacturer, then the warranty will no longer

 

be valid and shall become the full responsibility of the 

modifying person/organisation. Claims based on defects 

attributable to improper installation and/or application, and

 

the consequences thereof, are excluded. 

In case of component failure due to abnormal circumstances

 

or at end of life, replacement must be carried out by a suit-

ably qualified and trained professional.

Installation Procedure

1)

Prior to electrical connection, proceed with mechanical

 

installation by firmly fixing stirrup 

A

 

to optional mounting

 

accessory or directly to a suitable surface. 

Aim luminaire.

Caution:

 

Make sure not to damage any electric cable,

 

water pipe or other devices while drilling holes.

2)

Switch off 

and isolate 

the mains electrical supply. 

3)

Remove gear box cover 

B

 

by releasing screws 

C

.

4)

Check that rating shown on the luminaire label conforms

 

with the mains electrical supply.

5)

Feed 

suitable 

mains supply cable 

D

 

through cable gland 

E

.

 An additional gland is supplied to allow loop through

 

of supply cabling

 or alternative DMX cabling 

arrangements

6)

Connect to the correspondingly marked contacts of 

terminal 

F

, according to the wiring diagram. 

Tighten cable gland 

E

 

firmly.

7)

Reposition gear box cover 

B

 

and tighten screws 

C

 

evenly.

8)

Loosen the two screws 

G

 

slightly. Aim luminaire in

 

desired direction, tighten screws 

G

 

firmly (

100Nm

).

In addition, tighten screw 

H

 

to secure orientation of 

luminaire. 

B

F

C

E

A

H

G

D

160

145

ø 260

70

ø 18

ø 14

44

165

190

ø 340

70

ø 18

ø 14

44

175

195

ø 385

60

44

ø 18

ø 14

FLC2

3

0

FLC240

FLC260

ON-OFF7/7ADVANCED

BASIC

1-10V

DALI

DMX

Maintenance

Apart from cleaning the product’s exterior surfaces, no 

special maintenance work is required. 

Clean only with a 

cloth and water

Do not use high-pressure cleaners.

Protect our environment: Discard used LEDs in compliance

 

with the most recent environmental legislation.

Windage area

FLC2

3

0:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

0,054 m²

FLC240:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,090 m²

FLC260:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0,116 m²

Weight:

FLC2

3

0:  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

 

max. 9,1 kg

FLC240:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 13,8 kg

FLC260:   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . max. 18.8 kg

ø 5,5 – 12 mm

0,14 – 2,5 mm

2

DMX-Power

Notice:

 

In case the luminaire is equipped with an optional

ly 

available surge protector, the function can get tested if the

 

signal LED is lit green when the supply voltage is turned on.

In case the surge protector is defective, the LED device gets

 

automatically disconnected from the mains supply. 

If the signal LED is not lit, the luminaire is not functioning.

Tools required

–  Screwdriver TX 25

–  Screwdriver TX 40

–  Screwdriver with blade

 

3x1

Screwdriver TX70

Wiring Diagram

WE-EF Eco Step Dim® Advanced and

non dimmable luminaires

Class I

 

Phase to 

L1

, Neutral to 

N

 

and Earthing to 

WE-EF Eco Step Dim® Basic

Class I

 

Phase to 

L1

, Control Phase to 

L2

Neutral to 

N

 

and Earthing to 

1-10V / DALI / WE-EF Eco Step Dim® Dynamic

Class I

Phase to 

L1

, Neutral to 

N

and Earthing to 

1-10V, DALI, DMX to 

+

and 1-10V, DALI, DMX to 

Torque

Screw

T

orque

M4

max.

2,0 Nm

M5

max.

4,0 Nm

M6

max.

6,0 Nm

M8

max. 15,0 Nm

M16

max. 100,0 Nm

Da

Da

Shield