4
ON-OFF / ADVANCED
1-10 V
DALI
BASIC
Anschlussplan
WE-EF Eco Step Dim® Advanced und
nicht dimmbare Leuchten
SKI
Phase an
L1
, Neutralleiter an
N
, Schutzleiter an
SKII
Phase an
L1
, Neutralleiter an
N
WE-EF Eco Step Dim® Basic
SKI
Phase an
L1
, Steuerphase an
L2
Neutralleiter an
N
und Schutzleiter an
SKII
Phase an
L1
, Steuerphase an
L2
, Neutralleiter an
N
1-10V / DALI
SKI
Phase an
L1
, Neutralleiter an
N
, Schutzleiter an
,
1-10V an
+
und
–
, DALI an
D
SKII
Phase an
L1
, Neutralleiter an
N
,
1-10V an
+
und
–
, DALI an
D
Wiring Diagram
WE-EF Eco Step Dim® Advanced and
non dimmable luminaires
Class I
Phase to
L1
, Neutral to
N
and Earthing to
Class II
Phase to
L1
, Neutral to
N
WE-EF Eco Step Dim® Basic
Class I
Phase to
L1
, Control Phase to
L2
,
Neutral to
N
and Earthing to
Class II
Phase to
L1
, Control Phase to
L2
, Neutral to
N
1-10V / DALI
Class I
Phase to
L1
, Neutral to
N
and Earthing to
,
1-10V to
+
and
–
, DALI to
D
Class II
Phase to
L1
, Neutral to
N
,
1-10V to
+
and
–
, DALI to
D
D
Notice:
In case the luminaire is equipped with an optional
available surge protector, the function can get tested if the
signal LED is lit green when the supply voltage is turned on.
In case the surge protector is defective, the LED device
gets automatically disconnected from the mains supply.
If the signal LED is not lit, the luminaire is not functioning.
Hinweis:
Ist die Leuchte mit einem optional erhältlichen
Überspannungsschutz ausgerüstet, kann die Funktion über-
prüft werden, wenn die Signal-LED bei eingeschalteter
Versorgungsspannung leuchtet.
Ist der Schutz defekt, wird das LED-Betriebsgerät automa-
tisch vom Netz getrennt. Die Signal-LED leuchtet nicht, die
Leuchte ist ohne Funktion.