background image

3

Installation

The product must be installed and maintained by a 

VXLWDEO\TXDOLƂHGSURIHVVLRQDOLQFRPSOLDQFHZLWKODWHVW

 

building/construction and/or electrical regulations and 

relevant legislation.

Warning:

 Switch off mains electrical supply prior to 

installing and connecting the luminaire.

Notice:

,IWKHOXPLQDLUHLVPRGLƂHGE\DQ\ERG\RWKHU

than the original manufacturer, then the warranty will 

no longer be valid and shall become the full respon-

sibility of the modifying person/organisation. Claims 

based on defects attributable to improper installation 

and/or application, and the consequences thereof, are 

excluded.

Installation Procedure

1)  Switch off mains electrical supply. 

2)  Check that rating shown on luminaire label conforms 

with mains electrical supply.

3)  Loosen pressure screw 

R

 and packing ring 

G

. Place 

pressure screw 

R

 and packing ring 

G

 around mains 

cable 

C

 3XVKDWOHDVWFPRIPDLQVFDEOH

 C

 through 

spigot 

P

. Reposition packing ring 

G

 and tighten 

pressure screw 

R

 to secure mains cable 

C

.

5)  Loosen locking screws 

S

 to allow insertion of 

spigot

 P

 into spigot holder 

H

. Keep support screw 

T

 

tightened.

6)  Align and lock support screw 

T

 using spigot 

P

 

keyway.

7)  Push luminaire up until spigot 

P

 is fully recessed 

into spigot holder 

H

. Rotate luminaire counter-

clockwise and allow it to rest on locating support 

screw 

T

.

8)  Tighten locking screws 

S

, to lock luminaire in posi-

tion.

9)  Open luminaire by loosening screws 

L

. Carefully 

unhook lanyard

 I

.

/RRVHQVFUHZV

J

 (do not turn out). Rotate gear tray 

M

 counter-clockwise and pull out gently.

11) Connect mains cable 

C

 to terminal connector 

K

.

12) Return gear tray 

M

 to its original position and 

tighten screws 

J

.

13) Reconnect  lanyard 

I

 and close luminaire by tighten-

ing screws 

L

Reviews: