LED

Maintenance
Apart from cleaning the product’s exterior surfaces, no special maintenance work is required. 
Do not use high-pressure cleaners.

In case of component failure due to abnormal circumstances or at end of life, replacement must be carried 
out by a suitably qualified and trained professional.

Warning: Do not open luminaire while mains supply is switched on.

Caution: Risk of electric shock!

 

 

Important: To clean the glass panel, we recommend isopropanol 99% diluted 1:1 with distilled water. 
 
 
Installation
The product must be installed and maintained by a suitably qualified professional in compliance  
with latest building/construction and/or electrical regulations and relevant legislation.

Warning: Switch off mains electrical supply prior to installing and connecting the luminaire.

Caution: Risk of electric shock!

Notice: If the luminaire is modified by anybody other than the original manufacturer, then the warranty  
will no longer be valid and shall become the full responsibility of the modifying person/organisation.  
Claims based on defects attributable to improper installation and/or application, and the consequences 
thereof, are excluded.

Attention: The luminaire is factory-sealed and does not need to be opened during installtion. 
 
The installation on site must comply with local and/or national health and safety regulations.

Weight  

 

kg

for AFL110 

 

max. 4.70

for AFL120 

 

max. 6.95

for AFL130 

 

max. 8.60

Windage area 

 

m

2

for AFL110 

 

max. 0.092

for AFL120 

 

max. 0.146

for AFL130 

 

max. 0.191

Summary of Contents for AFL100 Series

Page 1: ...Type 1 and secondary Type 2 surge arrestors in compliance with EN61643 11 IEC61643 1 Do not open during installation This product is factory sealed Refer to the instructions contained in this document...

Page 2: ...65 191 5 683 111 733 111 250 89 250 89 300 89 300 89 Tool required Torx 20 45 5 mm Allen key 9 14 mm 1 2 5 mm2 Mounting height 3 8 m Installation horizontal light output downwards The photometric dat...

Page 3: ...tion and or electrical regulations and relevant legislation Warning Switch off mains electrical supply prior to installing and connecting the luminaire Caution Risk of electric shock Notice If the lum...

Page 4: ...screws J For horizontal mounting attachment can be set at 0 2 5 5 7 5 10 12 5 and 15 Adaptor to be ordered separately Using adaptor K diameter can be reduced from 76 mm to 60 mm or 42 mm Attach adapto...

Page 5: ...Installation Procedure 2 Pull the connecting cable through the pole Place the luminaire on top of the pole and tighten fasteners B tightening to a torque of 10 Nm Side entry Post top 40 60 x 100 B 76...

Page 6: ...ase 2 N Neutral Earthing c DALI L Phase N Neutral Earthing DA DA DALI control line 4 Table of maximum temperature AFL110 AFL120 and AFL130 AFL110 8 LED Power Ta 8 W 50 C 12 W 50 C 16 W 50 C 24 W 50 C...

Page 7: ...d Tel 41 22 752 49 94 Fax 41 22 752 49 74 info switzerland we ef com WE EF LIGHTING Thailand Tel 66 2 738 9610 Fax 66 2 175 2174 info asiapacific we ef com WE EF LIGHTING Australia Tel 61 3 8587 0444...