Maintenance 

 

5.1

 

Changing the canister 

 
Release the canister lid from the empty canister and refill it. 
Make sure not to overfill it. 

 

 

5.2 

Checking/ changing the dosing hose (see  3.1) 

 

The hose set of the pump is exposed to a mechanical anch chemical wear. 

For this reason the pump hose has always to be checked when the 
fragrance is refilled. This is  unavoidable to recognize damages in time and 

to change the pump set. In general, the pump set has to be changed 

every year. In case of aggressive fragrances, it hast to be changed more 
often. 

 

5.3 

Checking the dosing valve 

Some fragrance concentrates lead to disposals in the dosing tube and in 

the dosing valve. In this case   water may be pressed back at the splash, 
especially if the dosing hose is already damaged. For this reason check the 

dosing valve half a year, resp. when there´s a need to check it. For this 
purpose release the dosing hose and screw out the dosing valve. If you 

blow through the valve from the screw-in side it has to be hermetically 

sealed. If this is not the case flush it with water from the connection side. 
If this leads to no success insert a new valve. 

 

 

5.4

 

Cleaning the splash sprinkler 

 

After a certain operation time the splash sprinkler fossilises inevitably. For 

the cleaning screw off the sprinkler and clean it mechanically with weak 

acid. If you screw it up again Use only teflon band for sealing to keep the 
cleaning of the sprinkler simply. 

 

 

5.5

 

Cleaning the protection filter 

 

Depending on the contamination of the fresh water, the filter has to be 

cleaned in the supply. This is especially necessary shortly after the start-
up as there can occur some impurities in the pipeline and in the water. 

Therefore lock the ball valve, screw off the sealing plug of the filter, pull 
out the filter element and clean it up by flowing water. Install it again 

afterwards. Pay attention that the sealing is not damaged. 

 

Summary of Contents for SAUNA-Plus VII

Page 1: ...tment of the dosing 5 3 The dosing pump 6 3 1 Changing the hose set 6 3 2 Dosing valve 7 3 3 Fragrance canister 7 4 Installation Taking the unit into operation 7 4 1 Installation 7 4 2 Electrical conn...

Page 2: ...ve 9 into the water that streams to the oven A a result it is ensured that the fragrance concentrate is only dosed when there s pressure in the water tubing Additionally the installed security combina...

Page 3: ...connections for PTFE hose 6x1 push button for external control clock timer 2 2 The controller 2 2 1 Cycle pause in minutes The cycle time time from splash to splash is adjustable from 10 to 60 minute...

Page 4: ...T pump test of the fragrance pump for 20 seconds afterwards the operation LED blinks the controller waits for a readjustment T valve test of the solenoid valve for 20 seconds afterwards the operation...

Page 5: ...the controller The lead time can be adjusted to 0 30 60 or 120 seconds see wiring diagramme 2 2 7 Adjustment of the dosing The cycle time time from splash to splash is adjusted by the left rotary knob...

Page 6: ...It is extraordinary safe in its function an in addition to this very easy to handle see mounting Fragrance concentrates are extremely aggressive The used dosing hose is resistant against the most con...

Page 7: ...e canister The SAUNA Plus VII is delivered to be mounted on the wall the fragrance canister volume 1 5 l is pre mounted at the mounting plate 4 Installation Taking the unit into operation 4 1 Installa...

Page 8: ...an also be pre installed ex works The connection for the water supply at the ball valve is for the splash tubing 3 8 The fragrance canister has to be filled and the suction tube has to be hung into it...

Page 9: ...fore the oven If a non return valve is installed a tube cutter is absolutely necessary Option For the assembly and safe fixing of the splash sprinkler we offer a grommet with two threads 3 8 made of s...

Page 10: ...hen there s a need to check it For this purpose release the dosing hose and screw out the dosing valve If you blow through the valve from the screw in side it has to be hermetically sealed If this is...

Page 11: ...bove Check the function of the pump Pull the suction hose of the pump out of the fragrance canister does a air bubble appear in the hose Is it aspirated If yes the suction function of the pump works I...

Page 12: ...operation manual SAUNA VII 07 12 page 12 of 14 Open all ball valves Clean filter central filter in technical room Test every single function component with the test switch 6 Wiring diagramme...

Page 13: ...rommet felt EPDM 12709 pump motor 13557 mounting screws 17067 hose holder with dosing hose 13358 dosing hose with hose clamp 12782 Control housing ABS with imprint 16878 knob for control board 11031 v...

Page 14: ...nce flexible pressure tubing PTFE 4x1 Identification Article no ball valve MS 10423 oblique sitting filter MS 11479 protection group 11465 solenoid valve Va 15072 solenoid valve connector 13082 dosing...

Reviews: