WDT DUFTDOS-0-Compact Operating Instructions Manual Download Page 16

Fragrances dosing, type DUFTDOS-0-Compact

 

 

Index: 01 

Change date: 01/12/2017 

Operating instructions no.: BA DW 017-01 Duftdos-0-Compact EN 17630.docx 

Page 16 of 21 

7.1.3

 

Check function of the pump 

Realise the power-supply of the installation. The lock washer must rotate. 
 
Check suction function of the pump 
1.

 

Draw the suction hose of the pump out of the container. 

2.

 

The pump must suck air, forming an air bubble in the dosing pipe. 
If no air is sucked, the suction function is defect. 

3.

 

Afterwards deaerate the dosing pipe. 

See Section 5, Commissioning.

 

7.1.4

 

Fault removal 

CAUTION ! 
Fragrance concentrates can be harmful for the health!  
In case of works on the suction or dosing pipe, wear protection gloves or protection 
glasses. 

 

Fault table  

Fault 

Possible cause 

Actions 

The device does not connect 

 

Power supply interrupted 

 

Steam generator disconnected (if 
coupled with steam generator) 

 

Check the power supply 

 

Connect steam generator 

Device without function 

 

Control board defective  

 

Send in the device (do not open the 
housing) 

Dosing pump without function 

 

Pump motor defective 

 

Check / exchange the pump motor 

No fragrance dosing 

 

Container with fragrance con-
tainer empty 

 

Air in the dosing pipe 

 

Fragrance pump defective 

 

Hose of the dosing pump defect 

 

Roller carriers worn out 

 

Dosing valve blocked 

 

Fragrance concentrate dirty 

 

Refill container 
 

 

Deaerate dosing pipe 

 

Check / exchange the pump 

 

Exchange the hose 

 

Exchange the roller carrier 

 

Check / clean / exchange dosing valve 

 

Visual check of the fragrance concen-
trate on transparency and cleanliness. 
Exchange dirty concentrate 

Summary of Contents for DUFTDOS-0-Compact

Page 1: ...Item no 17630 Language EN Operating instructions Fragrances dosing for steam rooms Type DUFTDOS 0 Compact...

Page 2: ...ion 9 Selecting the place of installation 9 Installation information installation suggestion 9 Mechanical installation 10 Hydraulic installation 10 Electrical installation 10 5 Commissioning 11 Commis...

Page 3: ...device with appro priate accessories The operating instructions must be carefully read before using or maintaining the device and have to be stored in immediate proximity of the device Target group O...

Page 4: ...ed We provide a warranty for half a year on those parts Our ERP program requires an invoice for each delivery also for warranty services Customers will receive a credit note after returning the faulty...

Page 5: ...s and fragrances is provided in the safety data sheets of the fragrance manufacturers With the fragrance dosing a fragrance concentrate is mixed with the fragrance concentrate and is conveyed into the...

Page 6: ...trate in the steam pipe of steam rooms Function The fragrance concentrate is dosed through the hose pump passing the dosing pipe into the steam pipe The pump must be connected in such a way that it ca...

Page 7: ...pump according to the mainte nance plan or whenever fragrance is topped up 3 2 2 Dosing valve option The valve is a combined spring loaded non return valve and dosing valve In case of a defect of the...

Page 8: ...possible transport damage immediately after receipt ATTENTION The device can get damaged by frost or high temperatures Prevent exposure to frost during transport and storage Do not store the device ne...

Page 9: ...t 3 An electrical mains connection must be available 4 Good air supply and extraction are recommended for the installation room Installation information installation suggestion The device is assembled...

Page 10: ...team pipe 2 In case of a bigger distance between the installation place and the dosing valve install a transparent protec tion pipe for the dosing pipe if necessary 3 Connect the dosing pipe at the ri...

Page 11: ...ee Section 9 3 The device is provided with factory settings when it is delivered Adapt the regulation parameters during the start up on the desired operating mode Commissioning works Ensure that the d...

Page 12: ...y flammable CAUTION Fragrance concentrates can be harmful for the health Wear protective gloves and protective glasses See the safety data sheet of the manufacturer of the fragrance 1 Screw off the co...

Page 13: ...ve glasses ATTENTION Aggressive fragrance concentrates shorten the lifetime of the hoses If possible avoid aggressive fragrance concentrates Hint Refill consumables in due time If the container is emp...

Page 14: ...protect it against new connection Do not open the casing 7 1 1 Check replace hose set The device is mainly maintenance free The pump hose in the pump is subject to mechanical and chemical stress Each...

Page 15: ...arts of the hose ties 5 Install the hose set see Section 7 1 1 Check replace hose set Figure 11 Hose set spare parts Legend 16 Hose black 15 Hose holder 31 Marking 32 Plier 2x 7 1 2 Check the dosing v...

Page 16: ...protection gloves or protection glasses Fault table Fault Possible cause Actions The device does not connect Power supply interrupted Steam generator disconnected if coupled with steam generator Check...

Page 17: ...perating materials are subject to specific regulations In cases of doubt information should be available from the institution responsible for disposal at your place of operation When this is not possi...

Page 18: ...Fragrances dosing type DUFTDOS 0 Compact Index 01 Change date 01 12 2017 Operating instructions no BA DW 017 01 Duftdos 0 Compact EN 17630 docx Page 18 of 21 9 Documents Declaration of conformity...

Page 19: ...EN 17630 docx Page 19 of 21 Terminal plan No terminal diagrams necessary Commissioning protocol instruction This protocol is to be completed by the commissioning technician All warranty claims expire...

Page 20: ...ions no BA DW 017 01 Duftdos 0 Compact EN 17630 docx Page 20 of 21 Operating data sheet No operation data sheet necessary Maintenance protocol Perform the maintenance work listed in order to retain th...

Page 21: ...m Options Device Pos Description Item no WDT Dosing set Dosing set compete 12596 Dosing valve VA complete 3 8 4x1mm 3m dosing hose PTFE 4x1 mm Dosing valve Dosing valve VA complete 3 8 4x1mm 15108 Sea...

Page 22: ...ct installation 1 2 Settings made on control board and fragrance quantities adjusted to cabin size Type DS only Observe manufacturer specifications for fragrance concentrate 1 3 Hose pump roller suppo...

Page 23: ......

Page 24: ...ance year 20___ City street house number Device type Year of manufacture Serial number Activity Maintenance interval in months Month 1 Month 2 Month 3 Month 4 Month 5 Month 6 Month 7 Month 8 Month 9 M...

Reviews: