Fragrances dosing, type DUFTDOS 0-T
Index: 02
Change date: 01/07/2020
Operating instructions no.: BA DW 016-02 Duftdos-0-T EN 16621-17551.docx
Page 14 of 24
6
Operation / handling
General
The device is ready for use after the successful commissioning.
Hint !
The test button is foreseen to deaerate the dosing pipe.
Control
No adjustments on the control possible
Control - software
No software available
Top up consumables
CAUTION !
Fragrance concentrates can be harmful for the health!
Wear protective gloves and protective glasses.
ATTENTION !
Aggressive fragrance concentrates shorten the lifetime of the hoses.
If possible, avoid aggressive fragrance concentrates.
Hint !
Refill consumables in due time. If the container is empty, the pump sucks air and the
dosing pipe must be deaerated before continuing. Do not use any aggressive fragrance
concentrates attacking the hoses.
Fragrance concentrate
1.
Screw off the cover at the fragrance concentrate container.
2.
Bore a hole with a diameter of 7 mm in the cover.
3.
Screw the cover again.
4.
Place the container under the device.
5.
Glide the suction pipe into the container so that the end of the suction pipe touches the container bottom.