The MLC8A accepts, 75 Ohm, unbalanced, or 110 Ohm, balanced AES audio signals.

 

 

 

 

 

   

 

 

 

 

 

 

The operator must switch the input selector between the balanced and unbalanced AES

 

 

 

 

 

 

 

 

 

 

 

 

 

signals. The cluster of four LED illuminated push buttons labelled

(PRESET) 1, 2,

 

 

   

 

 

 

 

 

 

     

(MODE) 5.1 and ST

in conjunction with the push­push control in the

MASTER

level

 

 

 

 

 

 

 

 

 

   

 

 

 

control are used to make the input source selection. To make the selection,

 

 

 

 

 

 

 

 

 

 

 

 

 

simultaneously depress

PRESET 1, 2

and the

MASTER

knob until both

PRESET 1 and

 

 

   

 

 

 

 

 

 

 

   

 

2 LEDs

illuminate and release the buttons. Either the

5.1 or ST

button will be

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

illuminated.

5.1

represents 75 Ohms while

ST

represents 110 Ohms. Operating these

 

 

 

 

 

 

 

 

 

 

 

 

buttons will toggle between the 75 and 110 Ohm AES sources connected to the

 

 

 

 

 

 

 

 

 

 

 

   

 

MLC8A. 
NOTE: The selection function will time out and the buttons will revert back to their

 

 

 

 

 

 

 

 

 

 

 

 

   

 

normal function. 
 
The eight rotary level controls labelled

L, R, C, LFE, LS, RS, L

and

R

are used to adjust

 

 

 

 

 

 

     

 

 

   

   

 

   

 

the level of the individual signals being fed to the output of the MLC8A. These rotary

 

   

 

 

 

 

   

 

   

 

 

 

 

controls are equipped with concentric array of LED indicators that show the

 

 

 

 

 

 

 

 

 

 

 

 

proportionate value of the signal. Each rotary control incorporates a push­push switch

 

   

 

 

 

 

 

   

 

 

that instantly mutes that signal. When muted the concentric LEDs extinguish except for

 

 

 

 

 

 

 

 

 

 

 

   

the highest level LED which flashes to indicate the mute condition. The

MASTER

level

 

 

 

 

 

   

 

 

 

 

 

 

 

control adjusts over­all level of the proportional mix set by the eight individual level

 

 

 

   

 

 

 

 

 

 

 

 

 

controls. The

MASTER

level control also incorporates a push­push switch. Activating

 

 

 

 

 

 

   

 

 

 

this switch mutes all eight channels.  
 
It is possible to store two proportionate mixes in the MLC8A. Once the desired mix is set

   

   

 

 

 

   

 

 

 

 

 

   

 

push and hold a

PRESET

button until the concentric level indicator LEDs flicker,

 

 

   

 

 

 

 

 

 

 

 

 

(approximately five seconds) and the mix will be stored under that button. To recall a

 

 

 

 

 

 

 

 

 

 

 

 

 

   

setup press the appropriate 

PRESET 

the concentric level indicator LEDs flicker.

 

 

The

5.1

and

ST MODE

buttons allow toggling between full

5.1

and stereo only

 

 

 

 

 

 

 

 

 

 

 

 

 

 

monitoring. When the

ST MODE

button is pushed inputs one through six (AES 1, 2 and

 

 

 

 

 

   

 

 

 

 

 

     

 

3) are disconnected the seventh and eighth channels (AES4) are switched to the inputs

 

 

 

 

 

 

 

 

 

 

   

 

 

1 and 2 controls. This allows the operator to listen to the

ST L and ST R

on the

L and R

 

   

 

 

 

 

   

   

 

   

 

   

 

 

 

 

 

monitor speakers. In the 

ST 

mode the 

C, LFE, LS and RS

 controls are disabled.  

 

 

MLC8R Remote Panel

 

 
The MLC8R Remote Panel permits secondary control of the MLC8A from a remote

 

 

 

 

 

 

   

 

 

   

 

location. Controls and displays on the MLC8R mimic those on the main unit and status

 

 

 

   

 

 

 

 

 

 

 

 

 

 

changes can be effected from either location. 
 
The MLC8R mounts in a standard 19 inch rack and occupies one rack unit of space.

 

 

     

 

 

 

 

 

 

 

 

   

 

The unit is equipped with a single DB 9(M) connector for interfacing to the main MLC8A

 

   

 

   

 

 

 

 

 

   

 

 

 

unit. 

Summary of Contents for MLC8A

Page 1: ...MLC8A MULTI CHANNEL LEVEL CONTROL by Ward Beck Systems Rev Oct 01 2014 ...

Page 2: ...S422 control port for connection to an external controlling device such as the MLC8R remote panel Please refer to the rear panel layout diagram and the detailed connector diagram for connectors AUX and SERIAL COMM The MLC8A is factory calibrated to operate at the nominal level of 20dBFS 0 Other operating nominal levels such as 18 14 12 dBFS may be set provided it is specified at the time of order ...

Page 3: ...or the highest level LED which flashes to indicate the mute condition The MASTER level control adjusts over all level of the proportional mix set by the eight individual level controls The MASTER level control also incorporates a push push switch Activating this switch mutes all eight channels It is possible to store two proportionate mixes in the MLC8A Once the desired mix is set push and hold a ...

Page 4: ...MLC8A CONNECTOR LAYOUTS MLC8A CONNECTOR ASSIGNMENT MLC8A INTERCONNECT CABLE ...

Page 5: ......

Page 6: ......

Page 7: ......

Page 8: ......

Page 9: ......

Page 10: ...rminal Block AES EBU OUTPUTS Impedance 75Ω Unbalanced 110Ω transformer balanced Level 2 5V p p terminated Output 0 dbfs Noise Less than 100 dbfs Standard AES31D 1995 THD Less than 0 001 Type BNC Female 3 pin Terminal Block MONITOR OUTPUT Frequency Response 1 5 dBu from 20Hz to 20kHz Impedance 60Ω balanced Max Output 23 5 dBu Noise less than 70 dbfs THD Less than 0 05 Connector Type 3 pin Terminal ...

Page 11: ...ble such as fuses and lamps This warranty does not cover damages caused by misuse accident neglect unauthorized alteration repair by unauthorized personnel or damage caused by an act of God war or civil insurrection In no event shall Ward Beck Systems Ltd be liable for consequential damages Ward Beck Systems Ltd shall have the rights to final determination as to the application of this warranty Wa...

Reviews: