Wayne WWB Operating Instructions & Parts Manual Download Page 9

9

OPERATING INSTRUCTIONS & PARTS MANUAL

LIMITED WARRANTY

For one year for ALL Submersible Utility Pump models from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option 

for the original purchaser, any part or parts of its Multi-Use Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective 

in materials or workmanship. Please call Wayne Water Systems (800-237-0987) for warranty instructions. Be prepared to provide the model number and the serial 

number when exercising this warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. 
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, 

or failure to operate in accordance with Wayne Water Systems’ written instructions.

THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY 

OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM 

COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE 

AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY CONNECTED WITH 

THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY TORT 

(INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL WAYNE WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL 

DAMAGES. 

You 

MUST

 retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you 

MUST

 send a 

copy

 of the purchase receipt along 

with the material or correspondence. Please call Wayne Water Systems (800-237-0987) for return authorization and instructions.

DO NOT MAIL THIS FORM TO Wayne Water Systems.

 Use this form only to maintain your records.

MODEL NO._____________________  SERIAL NO._________________________ INSTALLATION DATE __________________________

ATTACH YOUR RECEIPT HERE

TROUBLE SHOOTING CHART

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or run

1.  Blown fuse or breaker

1.  Check pump housing or power cord 

for damage, before replacing fuse or 

resetting breaker. If in doubt call an 

electrician

2.  Low supply voltage

2.  Contact an electrician

3.  Worn motor

3.  Replace pump

4.  Impeller not rotating (jammed)

4.  If impeller will not turn, disconnect 

pump from power source and remove 

blockage (see Pg.7 for Inlet Screen 

and Impeller Cleaning Instructions)

5.  Thermal protector open

5a. Water temperature is too high, allow   

pump and/or water to cool

  b. Inlet clogged, remove debris

  c. Motor seized, replace pump

  d. Discharge clogged or hose kinked/

clogged. Clear blockage

Pump starts but delivers little or no 
flow

1.  Inlet clogged

1.  Clean debris from exterior of inlet 

screen and all debris filtering features

2.  Low supply voltage

2.  Contact an electrician

3.  Restriction discharge hose
4.  Discharge lift too high

3.  Unwind garden hose, remove any 

kinks or restrictions in hose

4.  Water level to end of garden hose is 

25 ft. or greater, reduce vertical lift.

5.  Impeller clogged

5.  Disconnect pump from power source 

and remove blockage (see Pg.7 for 

Inlet Screen and Impeller Cleaning 

Instructions)

Summary of Contents for WWB

Page 1: ...tion against line to ground faults only The ground fault receptacle does NOT limit the magnitude of fault current and will NOT prevent electrical shock Risque de choc lectrique Le disjoncteur de fuite...

Page 2: ...moment d inattention peut entra ner des blessures graves Dress properly Do not wear loose clothing or jewelry Pull back long hair Keep your hair clothing and gloves away from moving parts Loose clothe...

Page 3: ...caus s par le non respect des r gles de s curit our des pr cautions de base WAYNE Water Systems N EST PAS responsable des blessures corporelles ou des d gats mat riels qui pourraient r sulter d une ut...

Page 4: ...TO MOVE WATER STEP 1 GET TO KNOW YOUR PUMP STEP 2 CHOOSE THE DISCHARGE BEST FOR THE APPLICATION TOP DISCHARGE is perfect for water removal in tight spaces Laundry Tubs Window Wells Buckets etc SIDE D...

Page 5: ...INDICATOR WILL TURN RED NOTE At 70 F this can take approximately 10 minutes At lower temperatures time to turn off is extended UNPLUG PUMP WHEN WATER IS NO LONGER BEING MOVED YOUR PUMP FINISHED PUMPIN...

Page 6: ...ER 1 6 HP CIRCUIT REQUIREMENT 15 A minimum CONSTRUCTION MOTOR HOUSING Thermoplastic MOTOR SHAFT Stainless Steel IMPELLER Thermoplastic PUMP DISCHARGE 2 3 4 in Brass Hose Fittings PERFORMANCE Gal hr Mo...

Page 7: ...filtered from the outside in Sitting the pump directly on a loose dirty surface will not allow the filter features to work to their full extent 7 Always know where your discharge hose is placed An uns...

Page 8: ...impeller and inlet screen of all debris d Reposition cork gasket using alignment features taking care not to obstruct pump discharge openings e Reinstall inlet screen using caution not to overtighten...

Page 9: ...WAYNE WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES You MUST retain your purchase receipt along with this form In the event you need to exercise a warran...

Reviews: