DESCRIPTION

This pump is a high capacity, centrifugal pump suitable for lawn 

sprinkling or other applications where large quantities of water are 

required. 

UNPACKING

Inspect this unit before it is used. Occasionally, products are 

damaged during shipment. If the pump or components are 

damaged, return the unit to the place of purchase for replacement, 

or call Customer Support (800-237-0987).

SAFETY SIGNAL WORDS

To help recognize this information, observe the following signal words/
hazard classifications.

  Danger indicates an imminently hazardous 

situation which, if NOT avoided, WILL result in death or serious injury.

  La mention Danger indique une situation 

dangereuse imminente qui, si elle n’est pas évitée, ENTRAÎNE la mort ou 

des blessures graves.

  Warning indicates a potentially hazardous 

situation which, if NOT avoided, COULD result in death or serious injury.

  La mention avertissement indique une 

situation potentiellement dangereuse qui, si elle n’est pas évitée, risque 

d’entraîner des lésions corporelles graves ou même la mort.

   Caution indicates a potentially hazardous 

situation which, if NOT avoided, MAY result in minor or moderate injury.

 MISE EN GARDE

   La mention mise en garde indique une 

situation potentiellement dangereuse qui, si elle n’est pas évitée, 

pourrait entraîner des blessures mineures ou modérées.

  Notice indicates important information, that if 

NOT followed, MAY cause damage to equipment.

 

 This is the safety alert symbol. It is used to alert you to  

potential bodily injury hazards. Obey all safety messages 

that follow this symbol to avoid possible harm.

 NOTE: 

Information that requires special attention.

GENERAL SAFETY INFORMATION

CALIFORNIA PROPOSITION 65

This product can expose you to chemicals, including DEHP, 

which is known to the State of California to cause cancer, 

birth defects and reproductive harm. For more information, 

go to www.P65Warnings.ca.gov.

Ce produit peutvous exposer à des produits chimiques, 

notamment du DOP, reconnus par l’État de Californie comme 

étant cancérigènes et à l’origine d’anomalies congénitales 

et de problèmes de l’appareil reproductif. Pour plus de 

renseignements, visiter le site www.P65Warnings.ca.gov.

GENERAL SAFETY

1.  Read all manuals included with this product carefully. 

Be thoroughly familiar with the controls and the proper 
use of the equipment. 

  Risk of electrical shock. This pump is non-

submersible.

  Risque de choc électrique. Cette 

pompe n’est pas submersible.

  Pump only clear water. Do not 

pump flammable or explosive fluids such as gasoline, 

fuel oil, kerosene, etc. Do not use in a flammable and/or explosive 

atmosphere. Personal injury and/or property damage WILL result.

  Pomper uniquement de l’eau fraîche. Ne pas 

pomper de liquide inflammable ou explosif tel que l’essence, le mazout, 

le kérosène, etc. Ne pas utiliser dans un environnement inflammable 

et/ou explosif. Des blessures corporelles ou des dégâts matériels 

POURRAIENT en résulter.

  This pump is not designed to handle salt 

water, brine, laundry discharge or any other application which may 

contain caustic chemicals and/or foreign materials. Pump and/or 

property damage could occur if used in these applications and will void 

warranty.

Summary of Contents for WLS150

Page 1: ...10 ft 15 ft 20 ft 25 ft WLS150 15 Gal hr 4350 4200 3950 3700 3500 20 Gal hr 3950 3700 3450 3250 3050 25 Gal hr 3400 3200 3000 2800 2500 30 Gal hr 2950 2750 2500 2150 1700 WLS200 15 Gal hr 5300 5150 4...

Page 2: ...se damage to equipment This is the safety alert symbol It is used to alert you to potential bodily injury hazards Obey all safety messages that follow this symbol to avoid possible harm NOTE Informati...

Page 3: ...k stone or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through...

Page 4: ...nchement incorrect du moteur d une temp rature ambiante excessive sup rieure 100 F 38 C d une ventilation inad quate ou d une pompe ou d un moteur d fectueux INSTALLATION Protect pump from the element...

Page 5: ...nts or couplings will allow air to leak into the pipe and cause poor pump operation or difficulty priming Make sure to use pipe joint compound or plumber s seal tape on all threaded pipe connections L...

Page 6: ...and installation instructions DUG WELL CISTERN LAKE AND SPRING INSTALLATION Install a foot valve on the inlet pipe and lower into the water Locate foot valve no closer than 2 feet from the bottom of t...

Page 7: ...lector WLS150 Only CONNECTING WIRES Terminal cover must be in place for safe operation Ground in accordance with local and national electrical codes Keep fingers and objects away from openings and rot...

Page 8: ...take on the diffuser has an O Ring seal and is covered with a lubricant remove the O Ring and discard 7 Remove the black end cap from the back of the motor exposing the motor shaft end on the WLS200 y...

Page 9: ...but no water is delivered NOTE Check to make sure the pump is properly primed before looking for other causes Unscrew priming plug and see if water is in priming hole 1 Pump in new installation did n...

Page 10: ...description and number as shown in parts list Address parts correspondence to Wayne Water Systems 101 Production Drive Harrison OH 45030 U S A REPLACEMENT PARTS LIST Ref No Description Part Number Qt...

Page 11: ...IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE...

Page 12: ...NOTES 12 www waynepumps com...

Reviews: