TROUBLE SHOOTING CHART

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or run

1.  Blown fuse or breaker

1.  Check pump housing or power cord 

for damage, before replacing fuse or 

resetting breaker. If in doubt call an 

electrician

2.  Low supply voltage

2.  Contact an electrician

3.  Worn motor

3.  Replace pump

4.  Impeller not rotating (jammed)

4.  If impeller will not turn, disconntect 

pump from power source and remove 

blockage (see Volute and Impeller 

Cleaning Instructions)

5.  Thermal protector open

5a. Water temperature is too high, allow   

water to cool before pumping

  b. Inlet clogged, remove debris

  c. Motor seized, replace pump

  d. Discharge clogged or hose kinked/

clogged. Clear blockage

Pump starts but delivers little or no 
flow

1.  Inlet clogged

1.  Clean debris from exterior of volute 

and all debris filtering features

2.  Low supply voltage

2.  Contact an electrician

3.  Restriciton in discharge hose
4.  Discharge lift too high

3.  Unwind garden ose, remove any 

kinks or restrictions in hose

4.  Water level to end of garden hose is 

25 ft. or greater, reduce vertical lift.

5.  Impeller clogged

5.  Disconnect pump from power source 

and remove blockage(see Volute and 

Impeller Cleaning Instructions)

LIMITED WARRANTY

For one year for WWB model from the date of purchase, from an authorized dealer, Wayne Water Systems will repair or replace, at its option for the original purchaser, 

any part or parts of its Multi-Use Pumps or Water Pumps (“Product”) found upon examination by Wayne Water Systems to be defective in materials or workmanship. 

Please call Wayne Water Systems (866-928-7284) for warranty instructions. Be prepared to provide the model number and the serial number when exercising this 

warranty. All transportation charges on Products or parts submitted for repair or replacement must be paid by purchaser. 
This Limited Warranty does not cover Products which have been damaged as a result of accident, abuse, misuse, neglect, improper installation, improper maintenance, 

or failure to operate in accordance with Wayne Water Systems’ written instructions.

THIS WARRANTY IS IN LIEU OF ANY AND ALL OTHER WARRANTIES, OBLIGATIONS OR AGREEMENTS, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY 

OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE, AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM 

COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT. THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE 

AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING WITH RESPECT TO OR IN ANY WAY CONNECTED WITH 

THE PRODUCT, REGARDLESS OF THE SOURCE OR PROVIDER OF SUCH GOODS. IN NO EVENT, WHETHER AS A RESULT OF BREACH OF CONTRACT, WARRANTY TORT 

(INCLUDING NEGLIGENCE) OR OTHERWISE, SHALL WAYNE WATER SYSTEMS OR ANY AFFILIATE BE LIABLE FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL 

DAMAGES. 

You 

MUST

 retain your purchase receipt along with this form. In the event you need to exercise a warranty claim, you 

MUST

 send a 

copy

 of the purchase receipt along 

with the material or correspondence. Please call Wayne Water Systems (866-928-7284) for return authorization and instructions.

DO NOT MAIL THIS FORM TO Wayne Water Systems.

 Use this form only to maintain your records.

MODEL NO._____________________  SERIAL NO._________________________ INSTALLATION DATE __________________________

ATTACH YOUR RECEIPT HERE

Summary of Contents for WaterBug WWB

Page 1: ...PERIOD OF TIME FOR FURTHER INSTRUCTIONS DOWNLOAD OWNER s MANUAL ONLINE www waynepumps com product wwb STEP 1 GET TO KNOW YOUR PUMP 10 FT POWER CORD TOP DISCHARGE SIDE DISCHARGE CORD WRAP CORD CLIP HAN...

Page 2: ......

Page 3: ...n Brass Hose Fittings www waynepumps com PERFORMANCE Model HP Discharge Head 0 ft 5 ft 10 ft 15 ft 20 ft 25 ft WWB 1 6 Gal hr 1350 1190 1010 815 600 350 Please read and save these instructions Read ca...

Page 4: ...ed for non automatic use in clear water The unit is equipped with a 10 foot 3 prong grounding type power cord The motor is oil filled and sealed for cooler operation Both discharge fitting are designe...

Page 5: ...trical wiring must be performed by a qualified electrician Improper wiring could result in fatal shock Le c blage lectrique doit tre r alis par un lectricien qualifi Un c blage incorrect peut entra ne...

Page 6: ...teur de pompe avec des mains mouill es ou sur une surface mouill e ou humide ou dans l eau lorsque la pompe est connect e une source d alimentation PUMP OPERATION 1 This pump has been designed to atta...

Page 7: ...before servicing Improper use could result in death or serious injury D brancher l alimentation avant de proc der l entretien Une utilisation incorrecte peut entra ner la mort ou des blessures graves...

Page 8: ...28 7284 for warranty instructions Be prepared to provide the model number and the serial number when exercising this warranty All transportation charges on Products or parts submitted for repair or re...

Reviews: