INSTALLATION MANUAL

6

TROUBLESHOOTING

Symptoms

Possible Cause(s)

Suggested Remedies

Pump will not  
start or run 
 
 
 
 
 
 

1. Water level too low
2. Blown fuse or tripped circuit breaker 

3. Low supply voltage
4. Motor
5. Switch
6. Inlet clogged
7. Switch obstruction

1. Water must be at the appropriate level to activate switch 
2. If blown, determine cause and then either replace with proper 

sized fuse or reset breaker

3. Contact an electrician
4. Replace pump
5. Replace switch
6. Remove debris
7. Remove obstruction to verify free motion of switch

Pump starts and 
stops too often

1. Back-flow of water from discharge 

pipe

2. Switch
3. Check valve not functioning properly 

or leaking

1. Install check valve 

2. Replace switch
3. Remove and examine check valve for prop er in stal la tion and free 

operation. Replace check valve if necessary.

Pump shuts off 
and turns on 
independently 
of switch (trips 
thermal overload 
protection)

1. Switch
2. Switch obstruction
3. Obstruction in discharge pipe
4. Low supply voltage

1. Replace tether switch
2. Remove obstruction to verify free motion of switch
3. Remove obstruction in discharge piping
4. Contact an electrician.

TROUBLESHOOTING WARNINGS

ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY 

before 

installing, servicing or making any adjustments.

TOUJOURS METTRE LA POMPE HORS TENSION 

avant de procéder à 

l’installation, à l’entretien ou à des réglages.

LET PUMP COOL FOR A MINIMUM OF 2 HOURS BEFORE ATTEMPTING TO 

SERVICE. 

Submersible pumps contain oil that become pressurized 

and hot under normal operating conditions. 

LAISSER REFROIDIR LA POMPE PENDANT AU MOINS 2 HEURES AVANT 

D’ESSAYER DE LA RÉPARER. 

Les pompes submersibles contiennent 

de l’huile qui devient pressurisée et chaude dans des conditions 

normales de fonctionnement.

1.  Submersible pump models have permanently lubricated 

bearings and require no additional lubrication.

2.  Submersible pumps contain dielectric oil for cooling.  

Dielectric oil can be harmful to the environment.  Follow 
state environmental laws when disposing of oil.

3.  The pump motor is equipped with automatic resetting 

thermal protector and may restart unexpectedly.  Protector 
tripping is an indication of motor overloading as a result of 
operating the pump at low heads, excessively high or low 
voltage, inadequate wiring, incorrect motor conditions, or at 
the end of its life.

Summary of Contents for T50SW

Page 1: ...l DISCHARGE 2 in NPT T50SW F50SW 3 in NPT supplied 2 in Adapter 200SW 100SW 75SW Sewage Pump www blueangelpumps com PERFORMANCE Model HP Discharge Head 5 ft 10 ft 15 ft 20 ft T50SW 1 2 Gal hr 7680 660...

Page 2: ...ment mise la terre FOR ADDED SAFETY the receptacle must be protected with a ground fault circuit interrupter GFCI All wiring must be performed by a qualified licensed electrician and comply with the N...

Page 3: ...ACHEMINEMENT D EAU DESTIN E LA CONSOMMATION Ne pas utiliser la pompe pour transporter de l eau qui sera utilis e comme de l eau potable destin e la consommation La pompe doit tre utilis e uniquement...

Page 4: ...PUMP SHOULD BE USED when risk of property damage from high water levels exists UNE ALARME AUTONOME DE NIVEAU D EAU LEV OU UNE POMPE DE SAUVEGARDE DOIVENT TRE UTILIS ES en cas de risque de d g ts mat...

Page 5: ...discharge pipe size below that which is provided on the pump 7 If optional control device or float is used follow mounting instruction supplied with device or float 8 A union should be installed above...

Page 6: ...n of switch 3 Remove obstruction in discharge piping 4 Contact an electrician TROUBLESHOOTING WARNINGS ALWAYS DISCONNECT THE PUMP FROM POWER SUPPLY before installing servicing or making any adjustment...

Page 7: ...Replace tether switch 2 Remove obstruction to verify free motion of switch 3 Remove obstruction in discharge piping 4 Contact an electrician Pump operates noisily or vibrates excessively 1 Worn bearin...

Page 8: ...p Check in on your sewage pump and reset the GFCI if necessary Ensure the pump itself is standing upright Vibrations during operation can cause it to fall or tilt onto one side This can jam the float...

Page 9: ...t cover Products which have been damaged as a result of accident abuse misuse neglect improper installation improper maintenance or failure to operate in accordance with Blue Angel Pumps written instr...

Page 10: ...__________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _...

Page 11: ...__________ _____________________________________________________________________________________________ _____________________________________________________________________________________________ _...

Page 12: ...12 www blueangelpumps com...

Reviews: