Wayne SWS50-8.5FX Operating Instructions And Parts Manual Download Page 5

Operating Instructions and Parts Manual

5

www.waynepumps.com

SWS50-8.5FX

S

tep

 5:

Screw pipe tee onto pipe nipple.
Hand tighten.
All connections will be fully tightened 
in steps 7 & 8.

S

tep

 6:

Remove protective cover from tank’s outlet/
inlet, then screw hose-barb elbow onto 
tank.
Hand tighten.
All connections will be fully tightened in 
steps 7 & 8.

HOSE-BARB 
ELBOW

S

tep

 7:

With a pipe wrench, tighten pipe tee  
1 to 1-1/2 turns, aligning hose-barb with 
pump as shown. (Make sure pipe tee and 
nipple are tight to prevent leakage.)

S

tep

 8:

Tighten hose-barb 1 to 1-1/2 turns. Make 
sure the hose-barb points toward the top of 
the tank when tight.

Do NOT overtighten hose-barb elbow. 

Some hose-barb elbows are made of 

plastic, and overtightening may cause 

damage.

Summary of Contents for SWS50-8.5FX

Page 1: ...ystem Pre Charged Tank www waynepumps com Please read and save these instructions Read carefully before attempting to assemble install operate or maintain the product described Protect yourself and others by observing all safety information Failure to comply with instructions could result in personal injury and or property damage Retain instructions for future reference Operating Instructions and ...

Page 2: ...ed for pumping potable water in applications where the water is located less than 25 feet vertically from the pump A pressure switch is a standard feature The shallow well pump must be mounted to either a pre charged conventional type or free standing pressure tank Intended for indoor use only Installation of this pump outdoors unprotected from the weather may cause hazardous conditions and will v...

Page 3: ...0 OFF and is NOT to be changed will void warranty 11 Before installing the pump have the electrical circuit checked by a licensed or certified electrician to make sure the circuit is properly grounded 12 Make sure the line voltage and frequency of electrical current supply agrees with the motor wiring 13 Do NOT attempt repairs to the electric motor All repairs to the motor must be completed by a l...

Page 4: ...plumbing WASHER HEX NUT CARRIAGE BOLTS WASHER HEX NUT MOTOR END TANK OUTLET INLET Step 2 Wrap ALL external pipe threads with plumbers seal tape or other thread sealant NOTE Start tape about two threads from bottom of fitting Wrap tape 2 or 3 turns in the direction of the threads overlapping each turn Smooth tape over threads to make sure there are no bubbles or loose pieces of tape HOSE BARB PIPE ...

Page 5: ...tank Hand tighten All connections will be fully tightened in steps 7 8 HOSE BARB ELBOW Step 7 With a pipe wrench tighten pipe tee 1 to 1 1 2 turns aligning hose barb with pump as shown Make sure pipe tee and nipple are tight to prevent leakage Step 8 Tighten hose barb 1 to 1 1 2 turns Make sure the hose barb points toward the top of the tank when tight Do NOT overtighten hose barb elbow Some hose ...

Page 6: ...he hose clamps over the ends of the hose B Attach the hose with clamps to the hose barb using a twisting motion on the hose while pushing it over the hose barb A B Step 10 Tighten the hose clamps on the hose over the hose barb fittings If a leak is detected after system is installed tighten hose clamps just enough to stop the leak Do NOT overtighten hose clamps Do NOT exceed 40 in lbs of torque B ...

Page 7: ...well should be pumped clear of sand before installing the pump Sand will damage the pumping parts and seal The draw down level of the well should not exceed the maximum rated depth for the pump The capacity of the pump will be reduced and a loss of prime may occur PIPING Inlet piping may be copper steel or rigid PVC plastic Flexible pipe is prohibited on suction pipe inlet pipe MISE EN GARDE Un tu...

Page 8: ...O PUMP PACKER TYPE FOOT VALVE Figure 2 Figure 2 Illustration B Illustration B Figure 2 Illustration C DRIVE POINT TO PUMP IN LINE CHECK VALVE DUG WELL CISTERN LAKE AND SPRING INSTALLATION FIGURE 12 ON PAGE 14 1 Install a foot valve on inlet pipe and lower into water The foot valve MUST be at least 18 from the bottom of the well or sand or sediment WILL be drawn into the system MISE EN GARDE Le cla...

Page 9: ...re used run a wire directly to the metal well casing or use a ground electrode furnished by the power company There is only one proper ground terminal on the unit The terminal s is located under the pressure switch cover is painted green and is identified as GRD The ground connection must be made at this terminal Figure 5 The ground conductor must not be smaller than the circuit conductors supplyi...

Page 10: ...her de la source d alimentation puis dissiper toute la pression du système avant d essayer d installer de réparer de déplacer ou de procéder à l entretien Verrouiller le sectionneur de courant en position ouverte OFF Étiqueter le sectionneur de courant pour éviter toute mise sous tension imprévue Protect the pump from freezing during winter conditions MISE EN GARDE Protéger la pompe du gel pendant...

Page 11: ...raining and priming 3 Place rotating shaft seal member in position on impeller and press into place Take care not to press against polished seal surface 4 Position impeller on shaft and tighten securely Figure 11 5 Secure diffuser to seal plate using the two cap screws Be sure the arrow on the front of the diffuser is pointing up and the screws are orientated on a horizontal line as described in S...

Page 12: ...arts in reverse order 14 Wipe down the seal plate to remove any debris or loose rust 15 Push the ceramic seat of the shaft seal into the seal plate using the cardboard ring provided to keep the ceramic face clean You can use a little water or dish soap to lubricate the seal pocket to make assembly easier 16 Slide the square cut gasket over the flange on the seal plate make sure not to let the gask...

Page 13: ... control disphragm ruptured 7 Foot valve may be clogged or stuck closed 8 Pump not fully primed 9 Water level below maximum lift specification 10 Undersized piping 11 Gaseous well 12 Distorted venturi 13 Incorrect jet for application 14 Undersized pump 15 Pump cavitates sounds like pumping gravel 16 Low supply voltage 1 Lower suction pipe further into wall 2 Open faucet to allow air to vent while ...

Page 14: ... lined with brick stone or concrete to prevent cave in D DRIVEN WELL Pipe with a pointed screen is driven into the ground below the water table The depth is usually less than 50 feet Available diameters are 1 through 2 E DRILLED WELL A hole bored into the earth with machinery and lined with pipe Depths range from a few feet to over 1000 feet Common well diameters are 2 3 4 and 6 for domestic water...

Page 15: ...SSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT TO THE SALE OF THE PRODUCT THE REMEDIES AND OBLIGATIONS STATED IN THIS WARRANTY ARE THE SOLE AND EXCLUSIVE REMEDIES OF AND OBLIGATIONS TO THE OWNER FOR ANY AND ALL MATTERS ARISING ...