background image

Operating Instructions and Parts Manual

5

TROUBLESHOOTING

Minimal service is required for this pump. The motor housing of 

the pump is completely sealed and requires no internal service. If 

pump should fail to operate, perform the following troubleshooting 

guidelines: 
1.   Verify pumping height does NOT exceed 13 feet (See Figure 1). 

If pumping height is greater than 13 feet, this pump will NOT 
operate.

2.   Verify water depth is 1-3/4 inches or greater (See Figure 1).

  Do NOT disassemble or alter this product in any 

way. Failure to follow these instructions will result in serious injury or 

death, and will void warranty.

  NE PAS démonter ou modifier ce produit 

de quelque manière que ce soit. Le non-respect de ces instructions 

entraînerait de graves blessures ou la mort, cela annulera la garantie.

3.   To verify pump is operating correctly.

a.  Disconnect pump from power source.
b.  Connect hose adapter and discharge hose to pump.

13 FT MAXIMUM 

PUMPING HEIGHT

Figure 1 - Pumping Height

WATER LEVEL MINIMUM: 
1-3/4 INCHES

c.  Immerse pump in a bucket or tub of water at least 1-3/4 

inches in depth.

d.  Place the other end of the discharge hose outside the 

bucket, so the water will pump out.

e.  Plug power cord into a grounded 120 volt GFCI power 

outlet. The pump should start after 2 seconds of detecting 

water. Once the pump removes the water to a depth of 3/8 

inch, the pump will stop automatically. 

f.  If pump does NOT operate, unplug power cord and 

proceed to maintenance –refer to cleaning instructions.

4.   To verify discharge hose is free from a blockage.

a.  Connect hose to another water source such as a faucet. 

If water flows through hose, return to step 3a. If water is 

restricted, verify discharge hose is unwound. Remove all 

kinks, bends, or obstructions in hose.

b.   If pump is still NOT operating, refer to cleaning instructions

5.  If pump runs continuously, unplug the unit. Once unplugged, 

check for debris stuck inside the sensor body (Figure 3). 

Remove any trapped leaves, debris or dirt.

6.  If the pump cycles on and off too often the electronic switch may need 

cleaning. Unplug the pump and turn upside down. The sensor should 
be checked for debris or build up of mater on the sensor.

PRIMING HOLE

BASE SCREWS (4)

INLET SCREEN/ 
BASE

IMPELLER PLATE

Figure 2 - Priming Hole Location

 

  

WHEN REATTACHING THE BASE (INLET SCREEN), BE SURE THAT 

THE "PLUGGED" SCREEN IS ORIENTED BELOW THE SWITCH.

Figure 3 - Remove Debris From Sensor

CLEAN DEBRIS 

INSIDE SENSOR 

Summary of Contents for EEAUP250

Page 1: ...r 3 4 in Hose Threads Auto On Off Water Removal Portable Pump www waynepumps com PERFORMANCE Model HP Discharge 0 ft 5 ft 10 ft 15 ft 20 ft EEAUP250 1 4 Gal hr 3100 2350 1600 900 250 Operating Instruc...

Page 2: ...des secteurs marins NE JAMAIS placer la pompe dans une piscine pendant que des gens sont dans l eau Le non respect de cette recommandation POURRAIT entra ner la mort ou des blessures graves DESCRIPTI...

Page 3: ...other and can only be inserted one way into the outlet Do NOT handle plug connector near water Failure to follow these instructions will result in serious injury or death Utiliser seulement des fiches...

Page 4: ...supply before attempting to install service relocate or perform any maintenance Failure to do so could result in fatal electrical shock La pompe d marre automatiquement Toujours couper le courant avan...

Page 5: ...e discharge hose outside the bucket so the water will pump out e Plug power cord into a grounded 120 volt GFCI power outlet The pump should start after 2 seconds of detecting water Once the pump remov...

Page 6: ...igure 3 6 Remove base and impeller plate Figure 2 check for debris clean 7 Clean inlet screen Figure 2 8 Clean hole inside volute housing with a pin or paper clip Figure 2 Pump starts and stops too of...

Page 7: ...DING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE AND ANY RIGHTS OR REMEDIES AGAINST ANY PERSON OR ENTITY UNDER THE UNIFORM COMMERCIAL CODE OR OTHERWISE WITH RESPECT T...

Page 8: ...8 NOTES www waynepumps com...