background image

Self-Priming 

Transfer Pumps

Table of Contents

Descripion . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1
Unpacking  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1
Safety .Guidelines .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .1
General .Safety .Information  .  .  .  .  .  .  .  .  .1
Installation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .2
Operation .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .2
Maintenance  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .3
Troubleshooting .Chart . . . . . . . . . . . . . . . . . . . . . . . . . .4
Replacement .Part .Information .  .  .  .  . 6-7
Warranty . .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .8

Description

These .self-priming .transfer .pumps .are .
designed .to .easily .transfer .water .from .
one .point .to .another . . .Model .PC1, .12 .
Volt .Transfer .Pump .is .convenient .when .
normal .power .is .not .readily .available . . .
Typical .applications .include .removing .
water .from .pool .covers, .clogged .
drains, .stock .tanks, .water .basins, .boats, .
cisterns, .etc . .Model .PC2, .115 .Volt .
Transfer .Pump .is .great .for .household .
usage . . .Typical .applications .include .
removing .water .from .waterbeds, .
clogged .sinks, .basements, .etc . . .Note: .Do .
NOT .use .PC2 .in .pool .areas . .The .motors .
on .both .models .PC1 .and .PC2 .are .non-
submersible .

General Safety Information

CalIfornIa ProPoSITIon 65

 

This product or  

  its power cord may 

contain chemicals known to the State 
of California to cause cancer and birth 
defects or other reproductive harm. 
Wash hands after handling.

General SafeTy

 

Do not submerge  

  motor or allow 

motor to be exposed to water. Personal 
injury and/or death could result.  Keep 
pump and power cords away from 
liquids.  Model PC1 becomes very hot 
during operation.  

   

Do not pump gasoline or 
other explosive liquids. Do 
not operate pump where 
flammable or explosive fumes or gases 
are present as a fire or explosion could 
result. Pump should only be used to 
pump clear water.  Do not run pump 
dry.

1 . . Read .all .instructions .

before .operation .

2 . . . .Protect .electrical .cord .

from .sharp .objects, .hot .
surfaces, .oil .and .chemicals . . .Avoid .
kinking .the .cord .and .replace .
damaged .cords .immediately .

 

This pump has been 

  evaluated for use 

with water only.

Unpacking

Inspect .this .unit .before .it .is .used . .
Occasionally, .products .are .damaged .
during .shipment . .If .the .pump .or .
components .are .damaged, .return .
the .unit .to .the .place .of .purchase .for .
replacement . .Failure .to .do .so .could .
result .in .serious .injury .or .death .

reaD & follow all InSTrUCTIonS

Save TheSe InSTrUCTIonS 

Do noT DISCarD

Safety Guidelines

This .manual .contains .information .
that .is .very .important .to .know .and .
understand . .This .information .is .
provided .for .SAFETY .and .to .PREVENT .
EQUIPMENT .PROBLEMS . .To .help .
recognize .this .information, .observe .the .
following .symbols .

 

Danger indicates an  

  imminently 

hazardous situation which, if not 
avoided, WILL result in death or serious 
injury.
 

Warning indicates a  

  potentially 

hazardous situation which, if not 
avoided, COULD result in death or 
serious injury.
 

Caution indicates a  

  potentially 

hazardous situation which, if not 
avoided, MAY result in minor or 
moderate injury.
 

Notice indicates  

  important 

information, that if not followed, may 
cause damage to equipment.

noTe:

 .Information .that .requires .special .

attention .

Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. 
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or 
property damage! Retain instructions for future reference.

For .parts, .product .& .service .information

visit .

www.waynepumps.com

REMINDER: Keep your dated proof of purchase for warranty purposes! 

Attach it to this manual or file it for safekeeping.

321205-001 .11/08

operating Instructions & Parts Manual  

PC1 and PC2 Series

© .2008 .Wayne .Water .Systems

MANUAL

Summary of Contents for 321205-001

Page 1: ...ls Avoid kinking the cord and replace damaged cords immediately This pump has been evaluated for use with water only Unpacking Inspect this unit before it is used Occasionally products are damaged dur...

Page 2: ...luded 6 foot suction hose to inlet of pump Attach garden hose to outlet of pump There must be a gasket in place to insure that these connections are airtight otherwise the pump will not prime 2 Connec...

Page 3: ...on motor shaft 4 Reassemble gasket cover plate and cover plate screws Shaft Seal Replacement Motor shafts are sealed with factory pre lubricated lip type seals which are good for the life of the pump...

Page 4: ...r retain prime after operating 1 Air leak in suction line 1 Repair suction line by tightening inlet connection or replace 2 Impeller blocked 2 Remove blockage 3 Worn seal 3 Replace seal 4 Suction lift...

Page 5: ...PC1 and PC2 Series Notes www waynepumps com...

Page 6: ...ress any correspondence to Model number Wayne Water Systems Serial number if any 101 Production Drive Part description and number as shown in parts list Harrison OH 45030 U S A Operating Instructions...

Page 7: ...Seal 1 D Retaining Ring 1 E Brushes 2 2 Brush Kit 66063 WYN1 E Brushes 2 3 Water Suction Attachment 66064 WYN1 66064 WYN1 F Water Suction Attachment 1 G 6 ft Suction Hose 1 NOTE Replacement parts are...

Page 8: ...PENS ES WHATSOEVER IS EXCLUDED Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of incidental or consequential damages so the ab...

Reviews: