To set the custom temperatures, simply power up the thermostat to be added to the 

network and set the modes at the desired temperatures.  This must be done before adding 

the thermostat to the Room Key Controller.  The Room Key Controller will grab the 

temperature set points from the thermostat when it is added to the network.  Multiple 

thermostats are supported but only the temperatures from the first thermostat will be 

recorded.  The Room Key Controller will always set all thermostats in the room to the 

same temperature.   

 

This mode of operation is particularly useful when hotel guests manually change the 

thermostat temperature.  Once the card is inserted or removed, all thresholds will go back 

to the originally programmed setting. 

 

Custom Set Points Re-Programming 

 

To set new custom set points for the Room Key Controller follow the following 

procedure: 

 

1.

 

Power down all thermostats in the room. 

2.

 

Insert the key card in the slot.  Wait 15 seconds. 

3.

 

Remove key card from the slot.  Wait 15 seconds. 

4.

 

Power up all thermostats in the room and set all of the thresholds manually in the 

thermostats. 

5.

 

Insert the key card in the slot. –Room Key Controller will grab the new thresholds 

and program them into non volatile memory. 

 

Stand Alone \ Indicator Mode 

The Room Key Controller can be configured to act in Stand Alone mode (factory default) 

where all control functions for the room are controlled by the Room Key Controller or in 

Indicator mode where the Controller switches from Room Controller to Key 

insertion\removal sensor.  In this mode, the Room Key Controller sends key status 

information to another controller such as Hotel Manager AG. When the Room Key 

Controller is reset, it will automatically go to Stand Alone mode.  Indicator mode can be 

set via the parameter command which is only accessible with a compatible Controller. 

 

 

 

PARAMETER # 

PARAMETER 

NAME 

DEFAULT 

DESCRIPTION 

VALID 

VALUES 

Stand Alone 

Sets Stand Alone mode (1) 

or Indicator mode (0) 

0-1 

 

 

Summary of Contents for WDHKC-50

Page 1: ...ice 770 831 8048 Fax 770 831 8598 Certification Exhibit FCC ID KJ8 0003177 IC 3540A 0003177 FCC Rule Part 15 249 IC Radio Standards Specification RSS 210 ACS Report Number 09 0189 15C Manufacturer Way...

Page 2: ...factory the thermostat threshold is set to 72deg F If the ambient room temperature is cooler than the threshold the thermostat will switch to a heating mode If the temperature is warmer than the thres...

Page 3: ...thermostats in the room 2 Insert the key card in the slot Wait 15 seconds 3 Remove key card from the slot Wait 15 seconds 4 Power up all thermostats in the room and set all of the thresholds manually...

Page 4: ...n figure 1 FIGURE 1 2 Use appropriate hardware to mount wall bracket aligned with the hole in the wall Make sure the smooth side of the wall bracket is facing the wall and the rib side is facing out A...

Page 5: ...add to the network At this time you may also set the level dimmers 3 Release the operate button on the Z Wave node 4 LED will turn off indicating success NOTE If a controller is added to the network...

Page 6: ...the Wall Bracket NOTE The screws fit from the bottom of the Faceplate into the nutserts in the Wall Bracket Regulatory Information US and Foreign patents pending Z Wave is a registered trademark of Ze...

Page 7: ...device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation of the device Cet appareillage num rique de...

Reviews: