Wayne-Dalton Quantum 3214 Owner Installation And User Manual Download Page 10

10 

 

 

Step 11: Install Wireless Infrared Safety Sensors Wall Mounting Bracket 
(If Included)

 

 

Select a mounting position 5 inches above the floor to center line of wall bracket. 
The EMITTER and TRANSPONDER units must be mounted inside the door 
opening to minimize any interference by the sun; however, the sensors must be 
mounted against the door track. The brackets may be temporarily mounted to the 
wall (or jamb) with a #8 X1/2” screw provided and should be in contact with the 
door track. Leave this screw in place after installation is completed to prevent 
accidental rotation of beam sensor. 

It is very important that both wall brackets 

be mounted at the same height for proper alignment. 

 

Using the 1/4” x 3/4” lag screw provided, attach the wall mounting bracket to the 
wall. In some installations it may be necessary to attach wooden spacers to the 
wall to achieve the required clearance. Expansion bolts (not supplied) may be 
required to attach brackets to walls constructed of materials other than wood or 
gypsum. 
 
 

 

Step 12: Install Wireless Infrared Safety Sensor Bracket    

 

 

 
Attach the sensor bracket to the wall bracket using the 
two #8 x 1-1/2” screws supplied (make sure that the 
curved hooks protruding from the bracket are positioned 
over and in firm contact with the door track). 
 

Note:  

This opener is equipped with state-of-the-art wire-

less infrared safety sensors which are activated by door 
movement. It is extremely important to position and 
mount the sensor brackets in firm contact with the door 
track so that the sensors are immediately activated by 
the door movement. 

 
 
 
 

Step 13: Install Wireless Infrared Safety Sensor 

 

 

Open hinged cover on infrared safety sensors and remove battery protective paper strip. 
Observe proper battery polarity, as illustrated, in battery compartment. 

 

Identify the TRANSPONDER (green LED) and 
mount this unit on the right side (from inside the 
garage looking to the outside) of the garage door 
and the EMITTER (red LED) on the left side. This 
same right/left mounting procedure must be fol-
lowed on two and three door installations. 

 

Mount the infrared safety sensors to 
the sensor bracket keeping the soft 
washer between the sensor and sen-
sor bracket and then place the conical 
washer, lock washer and hex nut on 
the extender bolt, as illustrated. 
 
Keeping the sensors pointing in towards door and aimed at each other, 
tighten nut until there is enough friction to hold in place. Do not fully tighten 
until the final alignment has been completed. 

Summary of Contents for Quantum 3214

Page 1: ...Station Code Change and Programming 14 Trouble Shooting 28 Infrared Safety Sensors Alignment 15 Parts Breakdown Rail Assembly 29 Transmitter Code Change Programming 16 Parts Breakdown Power Head Assem...

Page 2: ...nstalling or servicing a garage door sys tem Use a sturdy non metallic step ladder AFTER INSTALLATION IS COMPLETE FASTEN THIS MANUAL NEAR GARAGE DOOR PERFORM PERIODIC SAFETY CHECKS MAINTENANCE AND ADJ...

Page 3: ...E D INSTALLATION APPOSEZ L TIQUETTE RELATIVE AU D SACCOUPLEMENT D URGENCE SUR LE DISPOSITIF OU PROXIMITE DE CE DER NIER NE BRANCHEZ PAS L OUVRE PORTE AVANT D Y TRE AUTORIS PAR LA NOTICE UNE FOIS L OUV...

Page 4: ...rared reversing sensors detect an obstruction in door path and react by reversing door 9 Multi Function Wall Station Wired wall station pro vides up down door motion control and independent overhead l...

Page 5: ...nsure that the door is balanced and working properly A door that binds sticks or is out of balance could cause severe injury Do not attempt to compensate for an improperly adjusted door by the install...

Page 6: ...vices on the garage door by securing lock latch to inside face of door with suitable screw Install only on a properly balanced garage door An improperly balanced door could cause severe in jury Have a...

Page 7: ...motor end if ladder is not high enough Open the door and place a 2 x 4 piece of wood along the top sec tion of the garage door Rest the double rails on the 2 x 4 as illus trated Support the top secti...

Page 8: ...utomatically when door is activated and a 4 minute time delay circuit automatically turns light off allowing ample time to en ter the house A fully open door with light blinking indicates an obstruc t...

Page 9: ...th circuit board snaps NOTE Insert bottom of circuit board behind bottom snap of wall sta tion base Pivot circuit board up until board snaps into place For best results press on circuit board between...

Page 10: ...1 2 screws supplied make sure that the curved hooks protruding from the bracket are positioned over and in firm contact with the door track Note This opener is equipped with state of the art wire less...

Page 11: ...entrapment protection It is very important that both wall brackets be mounted at the same height for proper alignment The brackets may be temporarily mounted to the jamb with a 1 flat head nail provi...

Page 12: ...n of the door and do not staple through wire Be sure to leave about 12 of excess wire at each end so you will have enough slack wire to mount units Note If wires must be lengthened or spliced into pre...

Page 13: ...elf check of the controls Check your local electrical codes If your local code requires permanent wiring use the specifications called for and in structions illustrated Permanent Wiring Procedure 1 En...

Page 14: ...ss any button on the wall station until instructed 1 Press the PROGRAM Switch button located on the garage door power head unit once The red PROGRAM STATUS light on the motor power head unit and overh...

Page 15: ...nsponder and set the second door trans ponder jumper to one of the other two positions A third door will use the remaining un used position Temporar ily remove the batteries from all but the door bein...

Page 16: ...rackets are mounted at the same height see Step 14 and re mount if necessary Additional minor adjustments can be made by lightly bending the mounting brackets see Figure 2 Once the alignment light com...

Page 17: ...ng Available only for 303 372 MHz combo models Note The following steps describe the process to change the Transmitter security code and to program the Transmitter IMPORTANT You MUST change the Transm...

Page 18: ...of the trolley position is required use the close travel adjustment screw located on the bottom of the motor head A 1 4 turn equals approximately 1 of trolley travel turn clockwise to decrease distan...

Page 19: ...Also see Adjustment 2 page 22 Contact Obstruction Sensing Adjustment Step 28 Setting Door Opening Travel Do not use adjustments to compensate for a poorly balanced door This will interfere with the p...

Page 20: ...sed Repeat this test procedure If the door opener still will not respond properly and fails this test the door may cause severe injury or death Have a qualified service person make repairs Step 30 Pro...

Page 21: ...case with a coin and remove old batteries Insert two CR2032 or equivalent coin cell batteries and snap case together Adjustment 1 Opening and Closing Force This garage door opener is built with a safe...

Page 22: ...n The opener is designed to automatically reverse the door during closing travel whenever it comes in contact with an object up to the last 1 inch of travel above the floor An object on the floor with...

Page 23: ...lire attentivement les r gles de s curit page 3 et les instructions suivanres Faire fonc tionner uniquement lorsque l ouvre porte est correctement r gl et que la port est visible et sans obstacle LIS...

Page 24: ...ng and causes the light to flash 7 If door stops travel for 1 second at midpoint during close and then continues to close it indicates that the batteries in the Wireless Infrared Safety Sensors are we...

Page 25: ...veral functions a It can be used to set a custom pet position see below b It can be used to set the opener s closing force See Adjustment 1 Page 21 To set a custom pet position start with the door in...

Page 26: ...ec Release both buttons Do not perform this step to train additional hand held transmitters Note This operation erases all previously trained transmitters Additional transmitters must be pro grammed u...

Page 27: ...pages 18 19 and 21 3 Perform safety reverse tests Step 27 and 29 Make any necessary adjustments Twice a Year Check chain tension If chain rests on bottom of rail adjust tension by turning the two chai...

Page 28: ...urns to fully open position and opener light flashes Door arm adjustment Close travel adjustment is set beyond normal door position Obstructions on floor Adjust rod in tube to provide 1 of cushion com...

Page 29: ...Coupling Base Assembly 1 6 308967 1 4 20x3 4 Machine Bolts 2 7 220966 Chain 7 Opener 1 20 21 251228 221014 5 16 18x2 Hex Bolts Spacer Tube 2 2 220967 Chain 8 Opener 1 22 220999 5 16 18 Kep Nut 4 22096...

Page 30: ...onder Unit 1 6 306486 Wiring Harness 1 21 260600 Wired Sending Unit 1 7 269028 Light Socket 1 21a 260599 Wireless Sending Unit 1 8 260552 Lens 1 22 252092 Limit Assembly includes items 10 27 26 1 9 25...

Page 31: ...nd overhead light on off control Unit includes an electronic lock feature that prevents opening the garage from any wireless device Key Cable Outside Disconnect Part 157277 Recommended for all vault t...

Page 32: ...he product was purchased within the warranty period Manufacturer may either send a service representative or have the product returned to the Manufacturer at Buyer s expense for inspection If judged b...

Reviews: