If the ambient humidity is lower than the setting humidity and the compressor is
stopped, the Humidity Control Symbol " " will flash, otherwise it will be off.
When the fan speed is set to high level, the symbol " " will light up; when the fan
speed is set to low level, the symbol " " will light up.
When the machine needs to be cleaned, the cleaning symbol " " will flash,
otherwise it is off.
When the machine is defrosting, the defrost symbol
"
"
will flash, and goes out
after finishing the defrosting process.
Power off Memory Function
After the device is powered on, it will automatically resume the working status before
power off.
·
If the machine's running before power outage, the machine will automatically enter
power-on status, and maintain the previous setting parameters.
·
If the machine's shut down before the power outage, then the machine will still be in
power-off status.
Defrost Function
When the dehumidifier is running at a lower temperature, the system will
automatically determine whether there is a presence of frost. If any frost exists, it will
defrost automatically.
The fan will run at high wind speed and the compressor stops when defrosting, and
switch back to the previous setting wind speed after that. The compressor can be
restarted then.
Temperature Protection Function
When the ambient temperature is higher than the Default Highest Temperature
(113°F), the system will enter high temperature protection, the small figure on the
screen will indicate "HH", and the compressor will stop.
When the ambient temperature is lower than the Default Lowest Temperature (39 °F),
the system will enter the low temperature protection, the small figure on the screen
will indicate "LL", and the whole machine will stop.
Cleaning Reminder
If the accumulative running time of the fan is ≥ 30 days, the machine can continue to
run, but it will keep prompting the "Cleaning" icon and it will not be able to be
removed even re-powered.
In power-off status, long press the "Speed" button for seconds, then the display
screen will show up for once, which means the "Clean" prompt has been released,
and the fan’s previous running time has been cleared.
Special Note:
The compressor features a "3 minutes delay protection" function—While the
dehumidifier is powered, the compressor can only start again 3 minutes after its last
shutdown.