background image

If the ambient humidity is lower than the setting humidity and the compressor is 
stopped, the Humidity Control Symbol "        " will flash, otherwise it will be off.

When the fan speed is set to high level, the symbol "         " will light up; when the fan 
speed is set to low level, the symbol "        " will light up.

When the machine needs to be cleaned, the cleaning symbol "       " will flash, 
otherwise it is off.

When the machine is defrosting, the defrost symbol 

"

"

 will flash, and goes out 

after finishing the defrosting process.

Power off Memory Function

After the device is powered on, it will automatically resume the working status before 
power off.

·

If the machine's running before power outage, the machine will automatically enter 

power-on status, and maintain the previous setting parameters.

·

If the machine's shut down before the power outage, then the machine will still be in 

power-off status.

Defrost Function

When the dehumidifier is running at a lower temperature, the system will 
automatically determine whether there is a presence of frost. If any frost exists, it will 
defrost automatically.

The fan will run at high wind speed and the compressor stops when defrosting, and 
switch back to the previous setting wind speed after that. The compressor can be 
restarted then.

Temperature Protection Function

When the ambient temperature is higher than the Default Highest Temperature 
(113°F), the system will enter high temperature protection, the small figure on the 
screen will indicate "HH", and the compressor will stop.

When the ambient temperature is lower than the Default Lowest Temperature (39 °F), 
the system will enter the low temperature protection, the small figure on the screen 
will indicate "LL", and the whole machine will stop.

Cleaning Reminder

If the accumulative running time of the fan is ≥ 30 days, the machine can continue to 
run, but it will keep prompting the  "Cleaning" icon and it will not be able to be 
removed even re-powered.

In power-off status, long press the "Speed" button for seconds, then the display 
screen will show up for once, which means the "Clean" prompt has been released, 
and the fan’s previous running time has been cleared.

Special Note:

The compressor features a "3 minutes delay protection" function—While the 
dehumidifier is powered, the compressor can only start again 3 minutes after its last 
shutdown.

Summary of Contents for PD1201B

Page 1: ...Home Dehumidi er Please read the manual carefully before using the unit PD1201B USER MANUAL...

Page 2: ......

Page 3: ...use of the dehumidifier Our dehumidifiers are widely used in family bedrooms bathrooms basements offices and storage rooms etc The dehumidifiers from provide quick and efficient operation to Waykar re...

Page 4: ...nternal damage it is very important to keep refrigeration units like this one upright throughout their journey Please leave it standing upright and outside the box for 24 HOURS before plugging it in B...

Page 5: ...Safety Instructions Errors and Protection Code Safety Note and Maintenance Methods Cleaning and Maintenance Warranty and Contact Us...

Page 6: ...ne power wiring must be in accordance with national wiring rules and power line should be connected to the reliable external Earth Line The fixed wiring of the machine connection must be equipped with...

Page 7: ...objects obstructing the air flow in the air inlet and outlet 6 Before moving the product turn off the power and drain out the water When moving the machine body should not be tilted more than 45 degre...

Page 8: ...Parts Description Continuous Drainage Port Schematic Diagram Note This picture shows the dehumidifier Outline Drawing Other models may vary a little from shape and size please prevail in kind...

Page 9: ...f the machine Used to set the humidity and timing value up Used to set the humidity and timing value down Press to confirm the parameters setting Used for setting the time Used to switch to high and l...

Page 10: ...an set a time within the range of 1 to 24 hours which can be set again if invalid If you press the function button or no operation after seconds you will exit the humidity setting status automatically...

Page 11: ...t automatically The fan will run at high wind speed and the compressor stops when defrosting and switch back to the previous setting wind speed after that The compressor can be restarted then Temperat...

Page 12: ...ine will not be controlled by the control panel 4 During the fault alarm press any key to cancel the alarm sound If the Error Code is still present please don t hesitate to contact Waykar Customer Ser...

Page 13: ...temperature range of 41 100 if the room temperature exceeds this range the product may not work properly Waykar reserves the right to change the product the above parameters are subject to change wit...

Page 14: ...SAFETY NOTE AND MAINTENANCE METHODS Place the drainage hose well when drain water conti nuously so as to flow the water freely If work in a cold temperature that could freeze the water then the contin...

Page 15: ...SAFETY NOTE AND MAINTENANCE METHODS...

Page 16: ...e filter back into the machine This dehumidifier dehumidifies through continuous drainage Please follow the below instructions to set up the drainage method 1 The machine is shipped with a drainage ho...

Page 17: ...Restore power 2 Turn on the switch 3 Plug in the socket 4 Replace the fuse 5 Check the error code ask seller for help Dehumidifier operating but room not dry 1 There is too much dust in the filter 2 T...

Page 18: ...ly if damage is caused by other factors including but without limitation of Please fill out all required fields and inlcude your Order ID Date of Purchased if applicable Order Number ready Warranty Ex...

Page 19: ......

Page 20: ...We are expecting to see our products fulfill your life and hear your voice Your satisfaction means a lot to us Please tag us if you share a snap on your social media...

Reviews: