2. Mounting instructions
2.1 Dimensions
2.2 Magnetic Tape
Only pair the sensor with magnetic tape WBA2. For detailed information on the WBA2 magnetic tape and how
to mount it please refer to its
The figures 1 and 2 shows how the sensor and the tape must be installed. Please note that the WBA2 magnetic
tape is fitted with two tracks: an absolute track on one side and an incremental track on the other side. Thus,
you must strictly comply with the mounting direction as indicated by the arrow on the tape!
2.3 Mounting the sensor
Figure 1
Make sure that the installation meets the system’s mounting tolerances shown in the figures 1 and 2 along the
whole measurement length. The system cannot work if the mounting direction is not abided!
Avoid contact between the sensor and the tape. Fix the sensor with two M3x20 mm cylinder head screws
(recommended tightening torque: 1.1 Nm). The recommended minimum bend radius of the cable is ≥42 mm.