52
•
SmartSensor V User Guide
Setting
Description
Details
Expansion Port A/B
Lets you set the baud
rate for expansion
port A and B.
These ports are
currrently not
available for use.
Response Delays (Milliseconds)
RS-232
Lets you set how long
the sensor will wait
before responding to
a received message,
shown in milliseconds.
Change this if
you’re using a
communication
device that can’t
quickly change
transmission direction
RS-485
Lets you set how long
the sensor will wait
before responding to
a received message,
shown in milliseconds.
Change this if
you’re using a
communication
device that can’t
quickly change
transmission direction.
Exp. A/B
Lets you set how long
the sensor will wait
before responding to
a received message,
shown in milliseconds.
These ports are
currrently not
available for use.
Advanced Comm Register
Simple Protocol
Allows you to either
enable or disable
Simple SmartSensor
protocol.
By default, Simple
protocol is enabled.
Simple protocol must
be disabled if you
are using a multidrop
network or if you
plan on using RTMS
protocol.
Flow Control
Enables or disables
flow control
handshaking on the
sensor. Enable this
feature by selecting
RTS/CTS
from the
drop-down menu.
Keep this set to
None
unless you are
using a device that
requires hardware
handshaking.
Note.
If you increase
the response
delay, you should
also increase
the additional
response wait time
that SmartSensor
Manager uses when
communicating