background image

EMC: This product complies with requirements of the following European
Community Directives: 89/336/EEC (Electromagnetic Compatibility) as
amended by 93/68/EEC (CE Marking).  Directive73/23/EEC (Low Voltage)

does not apply to this product.  However, electrical noise or intense electromagnetic
fields in the vicinity of the equipment may disturb the measurement circuit. Measuring
instruments will also respond to unwanted signals that may be present within the
measurement circuit.  Users should exercise care and take appropriate precautions to
avoid misleading results when making measurements in the presence of electronic
interference.

ENVIRONMENTAL CONDITIONS:

1.

 

Indoor Use.

2.

 

Operating Ambient:  0% to 80% R.H. (0 to 35 ºC); 0% to 70% (35 to 50ºC) R.H.

3.

 

Storage Temperature:  -20 to 60ºC, 0 to 80% R.H. with battery removed from
Temperature Converter.

ELECTRICAL SPECIFICATIONS:

MEASUREMENT RANGE

ACCURACY

INPUT PROTECTION

-50ºC

-20ºC

=(2.0% rdg + 2ºC)

-19ºC

350ºC

=(0.5% rdg + 2ºC)

351ºC

500ºC

=(2.0% rdg + 2ºC)

501ºC

1000ºC

=(2.9% rdg + 2ºC)

-58ºF

-4ºF

=(2.0% rdg + 4ºF)

-3ºF

662ºF

=(0.5% rdg + 4ºF)

663ºF

932ºF

=(2.0% rdg + 4ºF)

933ºF

1832ºF

=(2.9% rdg + 4ºF)

60Vdc & 24Vrms

ACCESSORIES:

TP-255

Replacement Bead Probe

TP-254

Immersion Probe with Handle

MH101K

Master Handle Probe

TP110K

Immersion Probe *

TP120K

Surface Probe *

TP130K

Air Probe *

*(TP110K, TP120K, & TP130K require MH101K Handle)

Summary of Contents for Meterman TC-253A

Page 1: ...Operator s Manual TC 253A Temperature Converter TM Temperature Converter...

Page 2: ...or such damage expenses or economical loss Some states do not allow limitations on how long implied warranties last or the exclusion or limitation of incidental or consequential damages so the above l...

Page 3: ...Temperature Converter from its packing you should have the following items 1 Temperature Converter 2 K type Bead Thermocouple 3 Operator s Manual FRONT PANEL Refer to Figure 1 and the following numbe...

Page 4: ...ter Set the Multimeter to DC mV or V range 5 Place the sensing point of thermocouple on the surface or environment to be measured 6 Wait until the reading stabilizes GENERAL SPECIFICATIONS This Temper...

Page 5: ...results when making measurements in the presence of electronic interference ENVIRONMENTAL CONDITIONS 1 Indoor Use 2 Operating Ambient 0 to 80 R H 0 to 35 C 0 to 70 35 to 50 C R H 3 Storage Temperature...

Page 6: ...qualified instrument service personnel To maintain a thermocouple in good condition observe the following items n Avoid excess bending n Don t overheat the thermocouple n Avoid chemical reactions tha...

Page 7: ...non warranty repair or for calibration should be accompanied by the following information or items company name customer s name address telephone number proof of purchase warranty repairs a brief desc...

Page 8: ...ting from Wavetek Meterman Specifications subject to change Wavetek is a trademark of Wavetek Wandel Goltermann Wavetek Meterman 2000 U S Service Center Wavetek Meterman 1420 75th Street SW Everett WA...

Reviews: