VCG and main
dial
wfthin
a
frequency
range.
Linear
operation is selected when the
button
Is
extended. Logarithmic
operation is
selected
when
the button
is
depressed.
8, 8 Generator MODE Controls
-
Selects
one
of
the
fol lowing
three modes:
CONT
-
8 released. Continuous output at
500 OUT 15 and 18 and SYNC OUT
(TTL)
17 connectors.
TAIG
-
8 and 9
pressed.
DC level
output
until generator triggered by the MAN TRIG 11
or with a
signal
at the TRIG I N connector 18 .
When
triggered,
the
generator output is one cycle
of waveform
fol lowed by
a
dc
level.
GATE
-
8 pressed and 8
released .
As for
TRIG
except
the o
u
tpu
t
is continuous for the
duration of the manual
or
external
trigger signal.
The last cycle started is
always
completed.
10 TIME Knob
-
Sets the
sweep
time by control
ling the
period
of
the sweep ramp generator.
1 1 Manual Trigger Button
-
Triggers or gates
the
output
signals
when generator mode is TRIG
o r
GATE ( 8
pressed).
In trigger
mode,
one
wavefo rm
cycle
is output when the
button
is
pushed. In gate mode,
waveform
c
y
c
les are con
tinuously output
as
long
as
the
button
is held in.
12 FUNCTION Selector
-
Selects-
one
of three
waveforms
or
when
all
three
b
u
t
to
n
s are released,
a dc
level
.
.
1 3 DC OFFSET Control
-
Offsets the 500
OUT
waveforms or
gives dc levels
from -
1 0V
to
+
1 0V
(
-
5V
to
+
5V into
500)
at 15
and
from
- 1 V
to
+
1 V
(
-
0.5V
to
+
0.5V
into
500) at
18.
An OFF position ensures
no
offset.
14 AMPLITUDE Control
-
Ccw
rotation
reduces
waveform amplitudes at 1 5 and 16
by
30
d
B
.
DC and offset voltages
are
not affected
by thi s
control.
15 SOO OUT HI Connector
-
The
main
output
of
the generator at
the
function selected. Maximum
20
Vp-p (1 0 Vjrp
into
500)
with 30 dB continuous
ampl itude
control .
500 sou rce
im
ped
ance.
18 500 OUT LO Connector
-
Same as 15 ex
cept 20 dB
(1 /1 0)
lowe r
in
amplitude.
1 7 TIL OUT
Con nector
-
A TI L
square
for
each
cycle
of
the
generator.
To
be used fOr syn
chronization
or
as
a TIL
signal capable
of
driv
ing 20 TIL
loads
.
1 8 TRIG IN Connector
-
Accepts a TI L
signal
to
trigger
or
gate
the
generator.
Triggers
on
the ris
ing (lOW
to
high) transition
and gates during the
positive
(high)
portion of the
triggering
Signal.
18 SWP OUT Connector
-
Supplies
a
ramp
waveform with an approximate 4V
peak into
an
open circuit. For use as a
horizontal
drive
signal .
Source impedance is 6000.
20 GCV OUT Connector
-
Provides
a
0 to
4V
open
circuit
outp
u
t
proportional
to the
f requency
of the main generator. For
use as a
horizontal
drive
signal.
Source
impedance
is 6000.
21 VCG IN Connector
-
Accepts
ac
or dc voltages
to proportionately
control frequency within
the
range
determined by the FREQ U E NCY
M U LTIPLIER 4
.
Positive voltage increases the
frequency set by the dial 1
;
negative
voltage
dec reases
the frequency. The VCG IN will not
drive
the generator
frequency
beyond the
nor
mal dial
limits of
a
range
.
Input impedance
is
2 kO.
3.2 OPERATION
Perform the initial
checkout
in S
ec
t
i
o
n 2
for
the feel of
the
instrument. Any
questions
c
o
n
c
e
r
n
i
n
g
individual
controls a
n
d connectors
may
be
answered
in
paragraph 3.1 .
3.2.1 Signal Termination
Proper
signal termination,
or
loading, of
the
generator
connectors is necessary for its specified operation.
For example,
the
p roper termination
of
either
of the
500 OUT
connectors
is shown in figure 3-2. Placing
the
500
terminator,
or 500
reSistance,
in
parallel
with
a higher impedance, matches the
receiving
instru
ment input impedance to
the
coax
characteristic and
gen erator output
impedance,
thereby
m'inimizing
signal reflection
or
power
loss on the li
n
e
due to im
pedance
mi:;;match.
The
input
and output
impedances
of the
generato r
connectors
are
listed
below.
Scans
by
ArtekMedia
=>
2011