December 2007
Page 17
90-005-0003 Rev X01
50 Watt Ka Feedmount BUC User Manual
G
ROUND
S
TUD
Located between connectors J3 and J4 is a ground stud which is screwed
into the main body of the Unit. This should be used to ground the Unit to
the rest of the system.
M
OUNTING
I
NTERFACE
•
The Unit is designed to mount to a plate via the 2 sets of 3 ¼-20 bolt
holes located on each side of the Unit. The plate should be designed to
be capable of carrying the weight of the Unit. That plate is the typically
attached to a feed arm or other platform. No conductive cooling is
assumed. Therefore, the function of the Unit’s mounting interface is
simply to enable meeting the system vibration and shock requirements.
MOUNTING HOLE PATTERN