Dynamics Section Controls
Compressor
(white knobs)
The compressor’s Ratio/Slope can be set from 1 to infinity (limiter).
The Threshold is variably adjustable from +10 dB to -20 dB.
When the Attack time switch is set to Slow (F.ATK off) attack time is auto-sensing and
program dependent. Fast setting (F.ATK) attack time is 1 ms.
Release time is adjustable from 0.1 to 4 seconds.
Expander/Gate
(green knobs)
The expander’s Threshold is variable from -30 dB to +10 dB.
Range is variable from 0 – 40 dB.
When the Attack time switch is set to Slow (F.ATK off) attack time is auto-sensing and
program dependent. Fast setting (F.ATK) attack time is 1 ms.
Release time is adjustable from 0.1 sec to 4 seconds.
The Gate switch toggles the section from an expander (default mode) into a gate.
Dyn To
Bypass bypasses the entire dynamics section. Note that selecting Bypass does not result in a
flat signal, but rather one which mimics the flat response of the SSL channel strip hardware.
Ch Out moves the dynamics to the output of the E-Channel, making it post-EQ.