Dynamics Sections Controls

 (top to bottom)  

 

1. Compressor 

(white knobs)

 

 

 

a. The compressor’s 

Ratio/Slope

 can be set from 1 to infinity (limiter).  

 b. 

The 

Threshold

 is variably adjustable from +10 dB to -20 dB.  

 

c. When the 

Attack

 time switch is set to 

Slow 

(

F.ATK

 off,) attack time is auto-

sensing and program dependent.  In the 

Fast

 setting (

F.ATK

,) attack time will be 

forced to 1 ms.  

 

d. Release time is adjustable from 0.1 sec to 4 seconds.  

 

2. Expander/Gate 

(green knobs)

 

 

 

a. The expander’s 

Threshold

 is variable from -30 dB to +10 dB  

 b. 

Range

 is variable from 0 – 40 dB.  

 

c. When the 

Attack

 time switch is set to 

Slow 

(

F.ATK

 off,) attack time is auto-

sensing and program dependent.  In the 

Fast

 setting (

F.ATK

,) attack time is 1 ms.  

 d. 

Release

 time is adjustable from 0.1 sec to 4 seconds.  

 e. 

The

 GATE

 switch toggles the section from an expander (default mode) into a 

gate.  