Waves ELECTRIC 200 User Manual Download Page 22

22

   

Electric 200

THE PREFERENCES DIALOG 
The preferences dialog allows configuration of Audio, MIDI, and User choices. 

Audio provides control over the following parameters: 
  • Device displays the audio devices available on the system. 
  • Output Channels allows selection of audio outputs from the selected device. 
  • Sample Rate is used to select sample rate. 
  • Control Panel (Windows) launches the selected ASIO device’s control panel for selection

  of buffer size and latency. 

   • Buffer Size (Mac) is used to select buffer size, which determines latency. 

MIDI provides control over the following parameters: 
  • MIDI Input device displays a list of available MIDI input devices on the current system. 

  Select the MIDI device for receiving MIDI data. 

  • Input Channel: Electric 200 Piano standalone is ready to receive MIDI in OMNI mode from all

channels. The MIDI channel control allows the selected MIDI device to receive MIDI input only

from certain channels, as selected in the checkboxes.

User > Load Previous Settings: When checked, the Electric 200 Piano application loads with the last settings used. Unchecked, Default 

settings load.

Summary of Contents for ELECTRIC 200

Page 1: ...Electric 200 Electric 200 Piano USER GUIDE...

Page 2: ...1 2 CONCEPTS AND TERMINOLOGY 4 1 3 COMPONENTS 5 1 4 FUNCTIONAL BLOCK FLOW DIAGRAM 5 CHAPTER 2 QUICK START GUIDE 6 CHAPTER 3 INTERFACE AND CONTROLS 7 3 1 INTERFACE 7 3 2 CONTROLS 7 3 2 1 Keyboard Cont...

Page 3: ...e answer base the latest tech specs detailed installation guides new software updates and current information on licensing and registration Sign up at the support site and you ll receive personalized...

Page 4: ...p on this era defining sound Made famous by music giants like Queen Supertramp and Steely Dan the timeless reed tone has been featured on countless classic hits For this instrument we have painstaking...

Page 5: ...under the related selection menus for virtual instruments under all supported DAW host applications Waves Electric 200 Piano works also as a standalone application It uses ASIO Windows or Core Audio M...

Page 6: ...module to create and control effects such as tremolo phasing stereo imaging chorus and reverb Use the bottom module to control the characteristics of the keyboard and the amplifier Navigating the pres...

Page 7: ...that was sampled with both a condenser mic and a dynamic mic Top The Multi Effect processor provides modulation effects and reverb 3 2 Controls 3 2 1 Keyboard Control At the very bottom there s a vir...

Page 8: ...the curve is linear Range 50 to 50 Initial Value 0 Reset Value 0 Continuous control Formant The formant control changes the sound character but not the pitch Each step equals a half tone This means t...

Page 9: ...ampled sound of the electric piano without the mechanics and the release keys sounds It controls the Main samples level in the overall mix Range 0 100 Initial Value 100 Reset Value 100 Continuous cont...

Page 10: ...nics control is the sampled sound of the electric piano mechanics without the Main and the Key Up sounds It controls the Mechanics thump samples level in the overall mix Range 0 100 Initial Value 25 R...

Page 11: ...o Reset Value Alt click does not affect the current mode of this switch Drive Controls the level of the amplifier overdrive Range 0 100 Initial Value 0 Reset Value 0 Continuous control Type There are...

Page 12: ...Reset Value 0 Continuous control Mid The Mid control is a bell filter at 900 Hz which can be increased or decreased by 18 dB Range 50 to 50 Initial Value 0 Reset Value 0 Continuous control Treble The...

Page 13: ...13 Electric 200 Volume Controls the output gain level after plugin processing Range 0 10 Initial Value 7 Reset Value 7 Continuous control...

Page 14: ...s on and off When the FX module is again turned on each section will return to its previous state Tremolo Section Tremolo On Off The Tremolo button turns the Tremolo section on or off Range Off On Ini...

Page 15: ...ned with respect to the host Turning the knob counterclockwise increases the Tremolo rate through music note duration values related to the host s BPM 1 32T 1 32 1 32D 1 16T 1 16 1 16D 1 8T 1 8 1 8D 1...

Page 16: ...nob The middle position 12 o clock is the slowest Free value Turning the knob clockwise from this position increases the rate from 0 25 Hz to 28 Hz When the knob setting is less than 12 o clock values...

Page 17: ...0 Continuous control Phaser Section Phaser On Off The Phaser button turns the Phaser section on or off Range Off On Initial Value On No Reset Value Alt click does not affect the current mode of this...

Page 18: ...g is less than 12 o clock values are defined with respect to the host Turning the knob counterclockwise increases the Phaser Rate through music note duration values related to the host s BPM 1 32T 1 3...

Page 19: ...wet mix of the signal into the chorus and determines how much the module oscillator will influence the delay The chorus engine contains four delays and four oscillators Range 0 100 Initial Value 25 R...

Page 20: ...Value 55 ms Reset Value 55 ms Continuous control ReverbTime Control the reverb time up to 6 seconds Range 0 4 sec 6 sec Default 2 sec Reset Value 2 sec Continuous control Reverb Damp Increases the le...

Page 21: ...one instrument It requires ASIO drivers for Windows or Core Audio for Mac OS X Opening ELECTRIC 200 exe Win or ELECTRIC 200 app MAC loads the ELECTRIC 200 Piano instrument and configuration preference...

Page 22: ...d latency Buffer Size Mac is used to select buffer size which determines latency MIDI provides control over the following parameters MIDI Input device displays a list of available MIDI input devices o...

Reviews: