ELECTRICAL SPECIFICATIONS
PARAMETER
SYMBOL
VALUE
UNIT
NOTE
ABSOLUTE MAXIMUM RATINGS
Supply Voltage (at Pin 14)
V
DD
+4.5 to +12.5
+3.3 to +6
VDC
WLD33ND, -3A, -2L, -3L
WLD33ND-HB
Output Current
I
LD
2.2
3.0
A
WLD33ND, -2L, -HB
WLD33ND-3A, -3L
Power Dissipation (T
AMBIENT
=25°C)
P
MAX
9
10
W
WLD33ND, -2L, -HB
WLD33ND-3A, -3L
Operating Temperature Range
(Case) [1]
T
OPR
-40 to +85
-40 to +45
ºC
WLD33ND, -2L, -HB
WLD33ND-3A, -3L
Storage Temperature Range
T
STG
-65 to 150
ºC
Weight
0.6
oz
17 grams
Size
1.28 × 1.30 × 0.31
in
32.5 mm x 33.0 mm x 7.9 mm
MODEL
PARAMETER
WLD33ND-HB
WLD33ND-2A
WLD33ND-2L
WLD33ND-3A
WLD33ND-3L
UNIT
NOTE
DRIVE CURRENT OUTPUT
Max Output Current
2.2
2.2
3
A
Compliance Voltage,
Laser Diode Load,
V
DD
= 5 V
3.6
V
I
LD
= 100 mA
3.5
V
I
LD
= 1.0 A
3.0
V
I
LD
= 2.0 A
N/A
N/A
2.8
V
I
LD
= 3.0 A
Compliance Voltage,
Laser Diode Load,
V
DD
= 12 V
N/A
10.6
10.6
V
I
LD
= 100 mA
N/A
10.4
10.4
V
I
LD
= 1.0 A
N/A
10.1
10.1
V
I
LD
= 2.0 A
N/A
N/A
9.8
V
I
LD
= 3.0 A
Rise Time
100
ns
I
LD
= Full Scale
Fall Time
200
ns
I
LD
= Full Scale
Bandwidth [2]
2
MHz
CC, Sine Wave, 2A
Slow Start – Delay Time
0.24
sec
Slow Start – Ramp Time
0.01
sec
Leakage Current [3]
0
mA
Noise & Ripple
22
26*
18*
µA
100mA, 100kHz -L models
only. See note below.
CONSTANT CURRENT CONTROL
Short Term Stability, 1 hour
25 to 50
200
200
ppm
T
AMBIENT
= 25°C
CONSTANT POWER CONTROL
Short Term Stability, 1 hour
0.01
%
T
AMBIENT
= 25°C
Long Term Stability, 24 hours
0.05
%
T
AMBIENT
= 25°C
[1] An internal thermostat has been added to activate Shutdown (SHD) when the internal temperature exceeds 105°C. The output will be
re-enabled after a 250 to 300 ms slow-start once the internal temperature drops below 95°C.
[2] Bandwidth in Constant Power mode depends on photodiode bandwidth.
[3] Leakage current specification is based on full current set by R
SENSE
. See
for information on setting the current range.
Minimum turn-on current in the 200 mA range is 350 μA. Minimum turn-on current in the 2 A range is 12 mA.
Noise:
*The WLD33ND and WLD33ND-3A have noise greater than 45 µA. To further reduce noise, the WLD33ND-2L and WLD33ND-3L
models are available. Constant Power (CP) mode is not available in the -L models.