background image

www.teamWavelength.com

© 2010

QCL500, QCL1000, QCL1500 Low Noise Quantum Cascade Laser Drivers

PAGE 21

QCL1500-00400-D

NOTICE: 

The information contained in this document is 
subject to change without notice. Wavelength 
will not be liable for errors contained herein 
or for incidental or consequential damages in 
connection with the furnishing, performance, or 
use of this material. No part of this document 
may be photocopied, reproduced, or translated to 
another language without the prior written consent 
of Wavelength.

SAFETY:

Other than two fuses, there are no user 
serviceable parts inside this product. Return the 
product to Wavelength for service and repair 
to ensure that safety features are maintained.

LIFE SUPPORT POLICY:

As a general policy, Wavelength Electronics, Inc. does 
not recommend the use of any of its products in life 
support applications where the failure or malfunction 
of the Wavelength product can be reasonably 
expected to cause failure of the life support device 
or to signifi cantly affect its safety or effectiveness.  
Wavelength will not knowingly sell its products for 
use in such applications unless it receives written 
assurances satisfactory to Wavelength that the 
risks of injury or damage have been minimized, the 
customer assumes all such risks, and there is no 
product liability for Wavelength. Examples of devices 
considered to be life support devices are neonatal 
oxygen analyzers, nerve stimulators (for any use), 
auto transfusion devices, blood pumps, defi brillators, 
arrhythmia detectors and alarms, pacemakers, 
hemodialysis systems, peritoneal dialysis systems, 
ventilators of all types, and infusion pumps as well 
as other devices designated as “critical” by the FDA.  
The above are representative examples only and 
are not intended to be conclusive or exclusive of any 
other life support device.

PATENTED TECHNOLOGY

Covered by U.S. Patents 6,696,887; 6,867,644 
and 7,176,755 Licensed from Battelle Memorial 
Institute. 

CERTIFICATION AND WARRANTY

CERTIFICATION:

Wavelength Electronics (Wavelength) certifi es  that 
this product met it’s published specifi cations at the 
time of shipment. Wavelength further certifi es that its 
calibration measurements are traceable to the United 
States National Institute of Standards and Technology, 
to the extent allowed by that organization’s calibration 
facilities, and to the calibration facilities of other 
International Standards Organization members.

WARRANTY:

This Wavelength product is warranted against 
defects in materials and workmanship for a period of 
1 year from date of shipment.  During the warranty 
period, Wavelength will, at its option, either repair or 
replace products which prove to be defective.

WARRANTY SERVICE:

For warranty service or repair, this product must 
be returned to the factory.  An RMA is required 
for products returned to Wavelength for warranty 
service.  The Buyer shall prepay shipping charges 
to Wavelength and Wavelength shall pay shipping 
charges to return the product to the Buyer upon 
determination of defective materials or workmanship. 
However, the Buyer shall pay all shipping charges, 
duties, and taxes for products returned to Wavelength 
from another country.

LIMITATIONS OF WARRANTY:

The warranty shall not apply to defects resulting from 
improper use or misuse of the product or operation 
outside published specifi cations.

No other warranty is expressed or implied. Wavelength 
specifi 

cally disclaims the implied warranties of 

merchantability and fi tness for a particular purpose.

EXCLUSIVE REMEDIES:

The remedies provided herein are the Buyer’s sole 
and exclusive remedies. Wavelength shall not be 
liable for any direct, indirect, special, incidental, or 
consequential damages, whether based on contract, 
tort, or any other legal theory. 

REVERSE ENGINEERING PROHIBITED:

Buyer, End-User, or Third-Party Reseller are 
expressly prohibited from reverse engineering, 
decompiling, or disassembling this product.

WAVELENGTH ELECTRONICS, INC.

51 Evergreen Drive 
Bozeman, Montana, 59715
phone:  (406) 587-4910  Sales/Tech Support
fax: (406) 

587-4911

e-mail:

 

[email protected]

web:

 

www.teamwavelength.com

 

REVISION HISTORY

REVISION

REV. A

REV. B

REV. D

DATE

20-Sep-10

10-Oct-10

9-Nov-10

NOTES

Preliminary Release

Beta Release

Product Release

Summary of Contents for QCL1000 LAB

Page 1: ...587 4910 or quietqcl teamwavelength com 1 Covered by U S Patents 6 696 887 6 867 644 and 7 176 755 Licensed from Battelle Memorial Institute Minimize spectral drift center wavelength jitter and linew...

Page 2: ...rt number TCH35P10R0JE ND 10 50 W metal film resistor QCL Pin 19 QCL Pin 20 Internally grounded Figure 2 Example Test Load NOTE At 2 A output current will be compliance voltage limited with a 10 resis...

Page 3: ...nt Inrush current requirement 6 TYP MIN MAX UNITS TEST CONDITIONS PARAMETER TAMBIENT 25 C TAMBIENT 25 C 24 V in to full scale to full scale large signal 90 full scale to full scale at 500 kHz IOUT 100...

Page 4: ...er Function Remote Enable Disable Remote Power On Status Outputs MONITOR Current Monitor Range Current Monitor Bandwidth 3 dB Current Monitor stability Accuracy Current Monitor to Actual Limit Monitor...

Page 5: ...ed Model QCL500 QCL1000 QCL1500 RMS noise A 100 kHz BW 0 4 0 7 1 0 Average Current Noise Density nA SHz 1 0 2 0 3 0 How noise measurements are made is detailed in WEI s Low Noise Measurement Protocol...

Page 6: ...FICATIONS continued There is a slight 2 overshoot when the driver is operating in current limit with the limit value set well below the setpoint We recommend that you operate with the limit above the...

Page 7: ...or Analog Input Voltage Not designed for high current return Ground can be used to ground chassis Positive DC power to the unit typically 24 V Negative DC power to the unit typically 24 V GROUND desig...

Page 8: ...f this limit Online at http www teamwavelength com support calculator soa soald php choose the model of QCL driver you will be using Enter your power supply and QCL characteristics to determine intern...

Page 9: ...sing the REMOTE inputs wire them now TTL compatible up to 12 V Pin 3 Remote Power On Pin 4 Remote Power On Pin 5 Remote Enable Pin 6 Remote Enable STATE Local Only All switches to right or ON FACTORY...

Page 10: ...g a power supply with the chassis not tied to ground WEI offers switching power supplies PWRPAK 24V a 20 pin cable WCB311 and a power supply kit WCB312 to simplify setup Twist wire pairs to minimize n...

Page 11: ...hts If the LED does not power on review REMOTE vs LOCAL switch settings Step 4 and the state of the REMOTE POWER ON signal Pin 4 referenced to Pin 3 7 Set Current Limit Zero Output Current Choose Curr...

Page 12: ...off ramp is 5 5 sec Flip the POWER switch to the OFF position The POWER LED goes out Turn off the power to the dual DC power supplies 10 Remove test load and wire in a Quantum Cascade Laser Wire the...

Page 13: ...or 50 Hz peaks Pin 15 on the 20 pin connector is ground It can be wired to a screw on the chassis to the mounting slots etc Note that despite the peak at 60 Hz 0 ot 100 kHz RMS noise for the two graph...

Page 14: ...PIN Ground Pin 12 10 k The STATUS pins output 12 V up to 25 mA With this typical hookup we assume 1 5 V forward voltage across LED and 1 mA drive current 12 V 1 5 V 1 mA 10 k Minimize cable length to...

Page 15: ...20 CABLE 4 cond 4 cond 4 cond 4 cond 6 cond 6 cond 6 cond 6 cond 6 cond 6 cond 2 cond 2 cond 1 cond 3 cond 3 cond 3 cond 2 cond 2 cond BLK WHT GRN RED BLU GRN ORG WHT RED BLK RED BLK BLK RED WHT BLK...

Page 16: ...00 Low Noise Quantum Cascade Laser Drivers PAGE 16 QCL1500 00400 D MECHANICAL SPECIFICATIONS 2 32 6 00 28 6 55 4 00 50 5 00 5 50 75 R 141 281 233 TYP 59 062 Dimensions are in inches mm Tolerance is 5...

Page 17: ...ver needs to be mounted by the baseplate mounting holes not supported by the solder joints The solder joints are not meant for mechanical support To use 8 screws instead of 1 4 20s for mounting a shou...

Page 18: ...NOTE C NOTES NAME PLATE 7 3 10 1 VOLTAGE ADJUSTMENT 5 M3 5 SEE NOTE B LED 82 1 8 15 MORE THAN 6m m SCREWS MUST NOT PROTRUDE INTO POWER SUPPLY BY C M3 TAPPED HOLES 2 FOR CUSTOMER CHASSIS MOUNTING AC L...

Page 19: ...e example SOA determination Device QCL1500 V 24 Volts VQCL 10 Volts IQCL 1 25 Amp Follow these steps 1 Determine the maximum voltage drop across the driver V VQCL and mark on the X axis Example 24 V 1...

Page 20: ...NTS The charts on this page can be used to determine if your design falls within the Safe Operating Area SOA for the QCL series driver that you are using For an example of how to use these charts refe...

Page 21: ...tronics Wavelength certifies that this product met it s published specifications at the time of shipment Wavelength further certifies that its calibration measurements are traceable to the United Stat...