Integrated Tests
Information
NCNT TEST
(No Connection No Test)
This test function ensures that the Device Under Test (DUT) is plugged into the TnT
appliance tester and that it is switched on.
If the DUT is not plugged in and the TnT appliance tester detects that no DUT is present,
plug in the DUT to continue the test. Confirm or ‘QUIT’ to return to the main menu.
If for some reason the NCNT circuit does not detect the DUT but it is actually plugged in
and turned on, the operator will need to override the TnT appliance tester to continue the
test.
To do this - press the F3 Key.
With an emphasis in the standard AS/NZ3760 for carrying out the live testing the TnT
appliance tester will indicate for you to check if the DUT is plugged in and switched on. If
the DUT is not plugged in and/or recognised, it may require a live test therefore making it
necessary for the operator to carry out a full functional Leakage Test (TnT-el & TnT+
appliance tester models only).
This function is to ensure that correct testing procedures are carried out in accordance
with the Standard AS/NZ3760.
TO NOTE:
i.
When using 3-Phase adaptors the NCNT function will need to be over ridden by
pressing the ‘OK’ key prior to the TnT appliance tester performing the assigned
test.
Some single Phase appliances controlled by contactors will require manual over
ride also. In some instances holding the ‘ON’ button of the DUT will enable the
NCNT function to work normally.
The TnT appliance tester ensures that the Device Under Test (DUT) is
plugged in and switched on. This test is also a part of all of the testing
functions of this unit.