background image

Wavecom

User Manual

+ Certificate of Warranty and Product Support Information

TnT RCD

Portable Appliance Tester

Summary of Contents for TnT RCD

Page 1: ...Wavecom User Manual Certificate of Warranty and Product Support Information TnT RCD Portable Appliance Tester ...

Page 2: ... Tester should be calibrated every 12 months A correctly calibrated tester is essential for ensuring testing accuracy is maintained and for complying with the AS NZS 3760 2010 To book your tester in for calibration go to https www wavecom com au calibration_services php Then send your tester to your nearest calibration service centre For Western Australian customers Wavecom WA Calibrations Unit 2 ...

Page 3: ...t 19 Leakage Test 20 Earth Continuity Test 20 Integrated Tests 20 No Connection No Test 21 Wavecom Tags 22 Tester Serial WinPATS Coupon Code Purchase Information Rear Cover TnT RCD Portable Appliance Tester IEC Test Lead 500mm Orange USB A to USB B Interface Cable Earth Lead with Alligator Clips 1800mm Black IEC Power Cable 10A units IEC 20 10 Power Cable with Circuit Breaker 20A Units 24 Month Co...

Page 4: ...ents please contact your dangerous goods adviser and or review the IATA website www iata org publications dgr Pages index aspx This is not intended to constitute legal advice and you should obtain your own professional advice Please contact Wavecom Instruments Pty Ltd for more information Competent Person To ensure that all electrical equipment or devices are inspected tested and tagged correctly ...

Page 5: ... red and A N is green there is a fault with the Mains Supply You may also see more than one or all of these turn red For more information see Mains Supply Test Page 25 Battery LEDs The battery LED indicators display how much charge is remaining in your TnT RCD Use the table below for reference 100 Battery is fully charged 80 60 40 20 LED 2 will be flashing 0 LED 1 will be flashing TnT RCD Testing ...

Page 6: ...s a FAIL Tag with a DANGER tag and remove the device from service TnT RCD Testing Menu Main Menu B Use the Enter button to switch between Menu A and Menu B All tests on Menu B require a Mains Power source Power Test Menu B F1 The Power Test is for the purposes of monitoring and performance of equipment The Power Test feature is for single phase appliances only The Power Test allows the user to tur...

Page 7: ... IEC socket of the TnT RCD then clamp it onto earthed metal on the appliance 5 If testing an RCD plug the IEC 550 Orange Cable into the IEC socket of the TnT RCD then plug it into a socket on your RCD and turn that switch on 6 Navigate to Main Menu B then press F2 to enter the Leakage Test Menu cont 7 Press a function key to start the test F1 Earth Leakage limit set to MAX then 5mA fail F2 Double ...

Page 8: ...Inspection For details refer to the First Test section If the device passed the Visual Inspection continue with the following instructions if not refer to the First Test section 2 Navigate to Main Menu B and press F3 to enter the RCD Menu then press F1 to select Time Test 3 Press F3 to enter the Time Test options menu to ensure your TnT RCD has the correct settings for the type of RCD cont 4 cont ...

Page 9: ...plied to the equipment times the current drawn by the equipment Both Watt and VA ratings have a use and purpose The Watt rating determines the actual power purchased from the utility company and the heat loading generated by the equipment Disclaimer Meter Mode is to be used for quick simple indicative electrical parameter measurements Providing reasonably accurate readings without the need to carr...

Page 10: ...ween the exposed conductive material metal and the TnT RCD appliance tester This is done by means of connecting the earth lead with the crocodile clip probe attached to a GOOD earth point paint coatings will not provide effective connections and the appliance plugged into the TnT RCD appliance testers test socket The Maximum allowable limit is less than 1 0Ω Class 2 Double Insulated Construction D...

Page 11: ...d this The Supply Mains Test checks the polarity and connectivity of the mains supply by LED s This test is also a part of all the testing functions of this unit If the central N E light is on red and you need to conduct load leakage tests DO NOT CONTINUE If you are carrying out standard Insulation and Earth Bond tests it is generally safe to continue This light will glow if a voltage difference l...

Page 12: ...but the most extreme environments Part no WCM TM TAGS B BLK BUR GN O R Y Super Heavy Duty TA Tags 100 Tags Suitable for all industrial and outdoor sites Part no WCM TA TAGS B BLK BUR GN O R Y Optional Accessories 500mm Metal Braid for Earthing Appliances Part No TnT ES 500 3 Phase Adaptor 20A 32A 5pin 5pin Part No WCM 3PH MADP HBC Fuse Part No WCM HBC10AM205 Isolation Transformer for RCD testing P...

Page 13: ...asino Street Welshpool WA 6106 P 08 9353 1943 F 08 9353 4319 E saleswa wavecom com au Wavecom VIC Mark Kennedy M 0430 299 164 P 03 9897 4711 F 08 8243 3501 E service wavecom com au Sold By Date of Purchase Purchase Information Tester Serial Number The TnT RCD is proudly designed and manufactured in Australia by Wavecom ...

Reviews: