Wave Wavebrite Installation & Operating Instructions Manual Download Page 5

WB12.rev01 

 

Fig 1.                       

 

 

Section 5. 

Installing the Components 

 

 

Fitting 

Wavebrite™. 

See Fig 1.

 

 

 

Locate a suitable position, refer to 

Section 1.4

 and 

Fig.1

Note the Wavebrite™ system is 

modular and each component and can be fitted remotely. Fix the mounting brackets and saddle 
clamps. The FILTER/STRAINER 1 will require the most attention and should be installed where 
it can be easily monitored visually and can be accessed with ease.  

 

Attach the filter housings to the mounting brackets using the screws provided; ensuring the flow 
direction is correct; there are arrows on the top filter housings and on the WHALE UNIVERSAL 
WATER PUMP. The arrows must point in the direction of flow from the WHALE GREY WASTE 
WATER SUMP towards the 

WAVEBRITE™ FILTER MODULE. The flow direction through the 

WAVEBRITE™ FILTER MODULE is left to right, but this can be changed by reversing the 
WAVEBRITE WB1 CARTRIDGE in the 

WAVEBRITE™ FILTER MODULE housing if required, 

note flow direction arrow on WAVEBRITE WB1 CARTRIDGE. 

 

Connect from the exit of Filter Strainer 1 to the pump and all the filters to the 

WAVEBRITE™ 

FILTER MODULE with the 15mm hose supplied, quick connect fittings are supplied. 

See the 

Whale Pipe Fitting Guide supplied in the information pack. 

 

The WHALE GREY WASTER WATER SUMP should be located so the head to the pump is no 
more than 1000mm and the required pipe connections must be pre-drilled.  The grey water 
supply, such as from showers and basins are to go to the top connections, no hose or hose clips 
are supplied for this. Connect from the lower 25mm connection to the Filter Strainer 1 using the 
25mm flexible braided hose, 2 no. hose clips should be used on each end, these are supplied. 

Galley waste water should be directed to the black water system due to the food waste 
content and if directed to the Wavebrite system it may significantly reduce cartridge life. 

A filter/strainer (not supplied) could be installed under sink to help prevent galley waste going to 
the WHALE GREY WASTE WATER SUMP and the Wavebrite system if required.

 

 

It is required to have enough space below the filter units (25mm) to remove the filter bowls when 
changing cartridges and at one end of the 

WAVEBRITE™ FILTER MODULE (660mm) 

check 

the system specifications at Section 4 above. 

 

Install the Tees and pressure gauges using thread tape. 

 

Make the electrical connections to the pump, hour meter and WHALE GREY WASTER WATER 
SUMP as per the instructions supplied with the electrical components and to required safety 
standards. Locate the hour meter in a panel or an appropriate position. All electrical connections 
to be carried out by and checked by a qualified marine electrical installer. 

See section 5.1 Fig 2.

 

CAUTION 

It is advisable to use 
two hose clamps on 
hose tails, so each 
connection is double 
clamped

.

  

 

 

 

NOTE 

Refer to Whale 
Water Systems 
Catalogue for further 
information

 

if 

required. 
 
whalepumps.com 

 

WARNING 

Electrical 
connections are 
required and to be 
carried out by and 
checked by a 
qualified marine 
electrical installer. 

 

 

Summary of Contents for Wavebrite

Page 1: ...INSTALLATION OPERATING INSTRUCTIONS WWW WAVEBRITE CO UK WWW WAVESTREAM CO UK ...

Page 2: ...lled by a float switch located in the WHALE GREY WASTE WATER SUMP which switches the pump on and off This filter system is designed to remove contaminants from grey water if galley waste is put through the system cartridge life could be drastically reduced Wavebrite is designed for used in all sizes of boat and can easily be scaled up for larger boats and Superyachts The Wavebrite filter modules c...

Page 3: ...nting brackets to a solid fixing point The position you mount the Wavebrite filter module pre filters and pump filter strainer in must allow for cartridge replacement Do not mount in direct sunlight Some consideration must be given at this time to location of the components the following all affect pump performance Suction hose length between the pump strainer grey waste sump and the pump If too l...

Page 4: ...m hose 16 1 Mtrs 25 mm braded hose 17 4 Hose clips 18 1 Instruction and information pack Refer to Whale Water Systems Catalogue for further information regarding WHALE PUMPS and the WHALE GREY WASTE WATER SUMP 44 0 28 9127 0531 info whalepumps com www whalepumps com Section 4 Wavebrite Grey Water Filter System Specifications FLOW RATE 1 15 Liters per min SYSTEM MAX PRESSURE 6 2 bar PRE FILTERS MAX...

Page 5: ...upply such as from showers and basins are to go to the top connections no hose or hose clips are supplied for this Connect from the lower 25mm connection to the Filter Strainer 1 using the 25mm flexible braided hose 2 no hose clips should be used on each end these are supplied Galley waste water should be directed to the black water system due to the food waste content and if directed to the Waveb...

Page 6: ...ack water system Plastic spanners can be supplied and should only be used to remove the filter bowls they should be replaced by hand and only hand tight The WAVEBRITE FILTER MODULE requires changing after 20 hours of operation Also change if pressure gauge PG3 reaches 4 bar during pumping It is opened by removing the plastic circular clip releasing the end cap which can then be removed allowing th...

Page 7: ... pass pump is fitted ensure direct pump out from the WHALE GREY WASTER WATER SUMP is permitted and reinstate the Wavebrite System as soon as possible Take ashore in proper containers any Wavebrite system cartridges to be disposed of at approved facilities at marinas lock stations or local authority waste disposal sites As far as possible use biodegradable detergents soaps and cleaning materials Al...

Reviews: