4. USAGE
EN
14
4. USAGE
4.1. Control panel
t tt
tt
tt
tt
tt
4.2. Functions
4.3. Spa cover and security
Once powered up, the LED displays the current water temperature automatically.
The temperature unit’s selector changes the temperature units from Celsiusdegress to
Fahrenheit degress.
Press the temperature adjustment buttons, then the screen will flasj. When it is flashing, you
can see the desired temperature. The value will increase or decrease 1 degree at once. The
temperature could be set betwenn 86°F to 108°F (30°C to 42°C).
To lock or unlock the control panel, press the Lock button and hold 3 seconds.
Lock the control panel when you are away to prevent other people changing your
settings.
Press the Bubble button to activate the bubble and massage system, the green indicator
light turns on. It can be turned off by pressing it again.
The bubble system will stop automatically after 30 minutes of operation. Re-activate the bubble function
by pressing the bubble button again.
When the filter button is on, pressing bubble button will alter the filter mode into bubble mode. The filter
indicator light will turn off and the bubble indicator light will turn on. If the bubble button is pressed again,
the bubble mode will be changed back to the filter mode.
Press the filter button to activate the water filtration. The green indicator light will turn on when
the filtration system is activated. Please note that filters should be changed every 7 days, or
until they become discoloured.
Note:
- If bubble fucntion is on, the filtration can’t be activated.
Press the heating button to activate water heating and filtering system at the same time. The
green indicator light of filter and red indicator light of heating will turn on at the same time.
The pump dpes not stop heating until the current water temperatire reaches the set tempera-
ture; and the heating system will restart after the current water temperature drops below 35°C
below set temperature automatically.
Maximum heating temperature: 108°F (42°C)
Important:
After 150 cumulation hours of filtration operations, an audible alarm will sound and
the LCD display will show the characters CHG, followed by FIL, to remind you to
change or clean the filter. You can hold the filtering button 5 seconds to turn off the
buzzing. The filtering system will turn off, you can press the button to activate the
filtering system again.
Note:
- With the heating system starting, the filtration system will start working together.
- After turning off the heating system, the filtration system will still work.
- If the bubble function is active, the filtration and heating fucntions cannot be activated.
After each use, the control panel must be locked and the pool must be coated with its top cpver and
it must be attached to the base protector with the safety buckles.
Each safety buckles has a lock system; closed buckle, the latch in up position locks the buckle, the
latch in down position unlocks the buckle.