Installation
Waukesha Cherry-Burrell
Page 10
95-03076
August 2008
Connecting Flush Supply
Line (Optional)
Connect the cavity cleaning supply to a suitable water supply to flush the vent/
drain (Figure 4) during operation of the processing system.
The flush supply line can be connected to a pipe system by 1/4" (6 mm) rigid or
flexible poly tubing.
Connect the supply line to the adapter connection with flexible poly tubing
(Figure 4).
WARNING:
During valve opening and CIP cleaning, fluid escapes from
the drain port. Drain off to prevent possible hazard to personnel.
Regulate the flush supply for pressures of 30 psi minimum, 50 psi maximum.
Maximum solution temperature is 180°F (60°C).
WARNING:
The cavity cleaning operation must fall within the fail-safe
control system. See “Cleaning” on page 15.
For PMO applications, consult the PMO for suitable water requirements.
WARNING:
PMO requires pasteurized water for water flushing in
pasteurized product applications.
WARNING:
Take proper precautions to safeguard the flush water
supply, such as installing backflow prevention devices.
Figure 4 - Connection of Flush Supply