Température de service

Température d’expédition 

et de stockage

0°C - +40°C

-10°C à +50°C

Alimentation électrique

230V ac 50Hz

Protection électrique

Classe II - IP33

Type de contact

Charge maximale

2 fils (contact libre) - Connecteurs à vis <1.5mm

2

Jusqu’à 8A - 250V ac 50Hz 

Radiofréquences

868 MHz, <10mW

Normes et homologations

Votre thermostat a été conçu con-

formément aux normes suivantes 

ou autres documents normatifs

EN 60730-1:2017 / EN 60730-2-9:2021 / EN IEC 61000-3-2:2019 + AMD1:2021

EN IEC 61000-3-3:2013 + AMD1:2017 + AMD2:2021 / EN 55014-1:2017

EN 55014-2:2015 / EN 55024:2010 + A1:2015 / ETSI EN 301 489-3 V2.1.1

ETSI EN 301 489-1 V2.2.3 / ETSI EN 300 220-1 V3.1.1 / ETSI EN 300 220-2 V3.2.1

EN IEC 63000:2018 / Regulation (EU) 2015/1188 / Regulation (EU) 2013/813

Caractéristiques techniques

Mode de configuration RF

Technical characteristics

Radio configuration mode

1.  Installez et branchez le récepteur en respectant les consignes suivantes : 

Prêtez une attention particulière au choix de l’emplacement de votre récepteur, en effet quelques précautions sont à prendre 
afin de garantir un fonctionnement optimal de votre installation :

-  Le récepteur radio fréquence ne devrait pas être placé trop prés de canalisation électrique, hydraulique ou de tout type 

d’appareil de communication sans fils (GSM, Wi-Fi…). Une distance d’environ 50cm vous garantira un fonctionnement optimal.

-  Veillez à couper l’alimentation électrique avant toute intervention sur les borniers de connexion.
- Brancher votre récepteur au secteur.
2.  Ensuite maintenez le bouton poussoir enfoncé pendant 5 s, le voyant RF vert doit s’allumer (fixe) indiquant que le récepteur 

est désormais en mode de configuration radio en attente de l’adresse de configuration d’un thermostat 

3.  Référez-vous à la notice du thermostat pour configure le thermostat en mode “RF Init”.
4.  Vérifiez que les signaux radio sont correctement reçus par le récepteur. Sur le récepteur, la led verte doit clignoter à chaque 

réception d’un signal radio provenant du thermostat.

5.  Sortez du mode de configuration Radio du thermostat. (se référer à la notice du thermostat).
6. Votre installation est prête à l’emploi.

1.  Install and plug the receiver into the following guidelines:  

Pay attention before the installation of your receiver, some routing rules should be make to guaranty an optimal working.

-  The receiver must be put at a minimum distance of 50cm of all others electrical or wireless materials like GSM, Wi-Fi router.
-  Before wiring work related to the receiver must be carried out only when de-energized. 
-  Plug your receiver to the power supply.
2.  Then press the Receiver push button during 5sec, the Green RF LED should lit up (fixed) indicating that the Receiver is now 

in radio configuration mode waiting for a thermostat configuration address.

3.  Please refer to the thermostat leaflet for enter the thermostat in “RF Init” mode.
4.  Verify that radio signals are correctly received by the Receiver. On the Receiver, the Green LED should blink at each radio 

signal received from the thermostat. 

5.  Exit the Radio configuration mode on the thermostat. (Please refer to the thermostat leaflet).
6. Now starting your installation is ready to works.

Environment (Temperatures)

Operating

Transport and storage

0°C - +40°C

-10°C to +50°C

Power supply

230V ac 50Hz

Electrical protection

Class II - IP33

Type of contact
Maximum Load

2 wires (free contact) - Screw connectors <1.5mm

2

Up to 8A - 250V ac 50Hz 

Radio Frequency

868 MHz, <10mW

Norms and homologations

Your thermostat has been designed 

in conformity with the following 

standards or other normative  

docmuents

EN 60730-1:2017 / EN 60730-2-9:2021 / EN IEC 61000-3-2:2019 + AMD1:2021

EN IEC 61000-3-3:2013 + AMD1:2017 + AMD2:2021 / EN 55014-1:2017

EN 55014-2:2015 / EN 55024:2010 + A1:2015 / ETSI EN 301 489-3 V2.1.1

ETSI EN 301 489-1 V2.2.3 / ETSI EN 300 220-1 V3.1.1 / ETSI EN 300 220-2 V3.2.1

EN IEC 63000:2018 / Regulation (EU) 2015/1188 / Regulation (EU) 2013/813

Summary of Contents for WAT BT-RRF FREE CONTACT

Page 1: ...F FREE CONTACT Wireless Wall receiver Installation manual EN FR ES NL RU SK HU DE IT User guide Manuel d utilisation Gu a de Usuario Gebruikershandleiding N vod na in tal ciu Telep t si tmutat Benutze...

Page 2: ...Mode L N t C 230VAC 50Hz A RF configuration button B Status LED yellow Fixed Power on LED Blink RF transmission C RF LED green Fixed RF configuration mode Flash RF reception OFF Standby Blink RF Alarm...

Page 3: ...V r s Nincs f t s Z ld Nincs h t s A RF configuratie knop B Status LED Geel Vast Stroom aan LED Knipperend RF transmissie C RF LED Groen Vast RF configuratie mode Knipperend RF ontvangst OFF Standby L...

Page 4: ...t correctement re us par le r cepteur Sur le r cepteur la led verte doit clignoter chaque r ception d un signal radio provenant du thermostat 5 Sortez du mode de configuration Radio du thermostat se r...

Page 5: ...etc Bij het aansluiten van de electrische draden mag de ontvanger niet met het electriciteitsnet verbonden zijn Nu kan de ontvanger aan het electriciteitsnet aangesloten worden 2 Druk vervolgens op d...

Page 6: ...2 1 EN IEC 63000 2018 Regulation EU 2015 1188 Regulation EU 2013 813 Technick parameter Prevedenie r diovej konfigur cie 1 e 50 GSM Wi Fi 2 5 3 RF Init 4 5 6 1 Nain talujte a pripojte prij mac podla n...

Page 7: ...stemperatur Transport Lagertemperatur 0 C 40 C 10 C bis 50 C Speisespannung 230V ac 50Hz Schutzklasse Schutzart Klasse II IP33 Schaltkontakt Schaltleistung 2 Dr hte freier Kontakt Schraubklemmen 1 5 m...

Page 8: ...i Direttive e Normative Europee EN 60730 1 2017 EN 60730 2 9 2021 EN IEC 61000 3 2 2019 AMD1 2021 EN IEC 61000 3 3 2013 AMD1 2017 AMD2 2021 EN 55014 1 2017 EN 55014 2 2015 EN 55024 2010 A1 2015 ETSI E...

Reviews: