![background image](http://html1.mh-extra.com/html/watts/vision-smart-plug-pr03-rf-230/vision-smart-plug-pr03-rf-230_user-manual_3786060006.webp)
6
EN
6. Types of installation
Option 1
:
Vision
®
Smart Plug
+ RF thermostat for heating regulation.
1. Switch on the
Smart Plug
.
2. Press the Button during 3 sec to switch to RF Init.
3. The LED should be flashing Red /Green indicating that the plug is now in radio configuration mode waiting for a
thermostat configuration address.
4. Please refer to the thermostat leaflet for enter the thermostat in “RF Init” mode.
5. Then The
Vision
®
Smart Plug
LED must be switched OFF and the thermostat should exit the RF init mode
to indicate correct paring between both elements. You can pair several
Vision
®
Smart Plug
to the same RF
thermostats.
Option 2
:
Vision
®
Smart Plug
+ RF Ther RF Central unit BT-CT02 RF or BT-CT03 RF for heating regulation
and remote control with mobile APP.
1. First step is to pair the RF thermostat to the Central unit.
2. Press the RF button on the
Smart Plug
during 3sec.
3. The RF LED should be flashing Red /Green indicating that the
Smart Plug
is now in radio configuration mode waiting
for a central configuration address.
4. Please refer to the leaflet of the Central unit for more explanation about the pairing mode “RF Init”. You must pair the
Smart Plug
as a heating device in the Central unit.
5. The RF LED on the
Smart Plug
will switch OFF and the Central will show a message to indicate correct pairing
between both elements. You can pair several receivers in the same room.
Option 3
:
Vision
®
Smart Plug
+ RF Central unit BT-CT02 RF or BT-CT03 RF for ON/OFF devices or light control, timer
mode and remote control with mobile APP.
1. Press the Button 3sec to switch the
Smart Plug
in RF Init mode.
2. The LED should be flashing Red /Green indicating that the
Smart Plug
is now in radio configuration mode waiting for
a central configuration address.
3. Please refer to the leaflet of the Central unit for more explanation about the pairing mode “RF Init”. You must pair the
Receiver as an ON/OFF plug or a light in the Central unit.
4. The LED on the
Smart Plug
will switch OFF and the Central will show a message to indicate correct pairing between
both elements. You can pair several receivers in the same room. Receiver will work in Timer mode; you have the
possibility to create a weekly program for ON/OFF period.
or
ON/OFF
Note for installations 2 and 3:
• You can pair several receivers. Pay attention! Before linking a new receiver with the Central unit, you have to
reset the receiver imperatively.
• In case of a thermostat in RF Alarm, the Smart Plug stops heating.